104 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author안유민-
dc.date.accessioned2023-06-30T01:29:51Z-
dc.date.available2023-06-30T01:29:51Z-
dc.date.issued2008-12-
dc.identifier.citationTransactions of the Korean Society of Mechanical Engineers, A, v. 32, NO. 12, Page. 1115-1122-
dc.identifier.issn1226-4873-
dc.identifier.urihttps://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01087158&language=ko_KR&hasTopBanner=trueen_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/182607-
dc.description.abstractThis paper presents a new microchip which can separate motile sperm by chemotaxis. The microchip was developed to create longitudinal concentration gradient in the microchannel due to diffusion. Linearly good concentration gradient of chemoattractant was generated without any fluid control devices. In sperm separation experiment with the developed microchip, mouse sperm was used as sample and acetylcholine was selected as chemoattractant. Human tubal fluid (HTF), buffer solution, was introduced into the microchannel of the microchip and attractants diluted in ratio of 1, 1/2, 1/4, 1/8, 1/16, 1/32 and 1/64 including control (DI water) were dropped in each outlet by 2 μl volume with micropippet. After 5min, 1 μl sperm solution was dropped into inlet of the chip. After 10 min, when sperms reached to the outlet by chemotaxis, we counted sperms in each outlet by using microscopy. Consequently, we could separate progressive motile sperm with the new microchip. In the experiment, the most sperms were isolated at the outlet dropped with 1/ 16 diluted solution. The optimal concentration gradient to induce chemotaxis was about 0.625 mg/ml/mm.-
dc.description.sponsorship본 연구는 2006년 정부(교육인적자원부)의 재원으로 한국학술진흥재단의 지원을 받아 수행된 연구임(KFR-2006-311-D00326)-
dc.languageko-
dc.subjectAttractant-
dc.subjectChemotaxis-
dc.subjectConcentration gradient-
dc.subjectDilution-
dc.subjectMicrochip-
dc.subjectMotile sperm-
dc.title주화성에 의한 활동성 정자 분리용 마이크로 바이오칩에 관한 연구-
dc.title.alternativeA study about microbiochip for separation of motile sperm by using chemotaxis-
dc.typeArticle-
dc.relation.no12-
dc.relation.volume32-
dc.identifier.doi10.3795/KSME-A.2008.32.12.1115-
dc.relation.page1115-1122-
dc.relation.journalTransactions of the Korean Society of Mechanical Engineers, A-
dc.contributor.googleauthorKo, Y.-
dc.contributor.googleauthorMaeng, J.-H.-
dc.contributor.googleauthorAhn, Y.-
dc.contributor.googleauthorHwang, S.Y.-
dc.sector.campusE-
dc.sector.daehak공학대학-
dc.sector.department기계공학과-
dc.identifier.pidahnym-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE