dc.description.abstractGenerally, a proportional-resonant controller is used to eliminate steady-state errors during the voltage-current control of a double-conversion uninterruptible power supply (UPS) in a stationary reference frame. Additionally, the feed-forward control compensating for the load current, which can be considered a disturbance of the voltage controller, can be used to improve the disturbance rejection performance. However, during the parallel operation of UPSs, circulating current can occur between UPS modules when performing both feed-forward control and droop control because feed-forward control reduces the circulating current impedance. This study proposes a feed-forward compensation technique that considers the impedance of circulating current. An additional feed-forward compensation technique is developed to enhance the disturbance rejection performance. The validity of the proposed feed-forward compensation technique is verified by the experiment results of the parallel operation of a 500 W double-conversion UPS module.en_US
dc.description.sponsorship본 논문은 2022년도 정부(산업통상자원부)의 재원으로 한국산업기술진흥원(KIAT)의 지원을 받아 수행된 연구임 (P0017120, 2022년 산업혁신인재성장지원사업)en_US
dc.languagekoen_US
dc.publisher전력전자학회en_US
dc.subjectUPS(Uninterruptible Power Supply)en_US
dc.subjectProportional-resonant controlleren_US
dc.subjectFeed-forward controlen_US
dc.subjectCirculating current impedanceen_US
dc.subject2-DOF(Two-Degree of Freedom) controlen_US
dc.title이중 변환 UPS의 병렬 운전 시 외란 저감 성능 향상을 위한 정지 좌표계 상의 전향 보상 기법en_US
dc.title.alternativeFeed-Forward Compensation Technique in Stationary Reference Frame for the Enhanced Disturbance Rejection Performance in Parallel Operation of Double-Conversion UPSsen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume27-
dc.identifier.doi10.6113/TKPE.2022.27.5.367en_US
dc.relation.page367-375-
dc.relation.journal전력전자학회 논문지-
dc.contributor.googleauthor류효준-
dc.contributor.googleauthor윤영두-
dc.contributor.googleauthor모재성-
dc.contributor.googleauthor최승철-
dc.contributor.googleauthor우태겸-
dc.sector.campusS-
dc.sector.daehak공과대학-
dc.sector.department미래자동차공학과-
dc.identifier.pidyoonyd-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > AUTOMOTIVE ENGINEERING(미래자동차공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE