227 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author안강호-
dc.date.accessioned2022-07-27T00:59:09Z-
dc.date.available2022-07-27T00:59:09Z-
dc.date.issued2021-03-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v. 79, NO 5, Page. 492-498en_US
dc.identifier.issn1976-8524-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://link.springer.com/article/10.1007/s40042-021-00225-9-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/171781-
dc.description.abstractThe transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) occurs via contact with contaminated surfaces and inhalation of large airborne droplets and aerosols. As growing evidence of airborne SARS-CoV-2 transmission has been reported worldwide, ventilation is an effective method of reducing the infection probability of SARS-CoV-2. This leads to such questions as "What is a sufficient ventilation rate for avoiding the risk of COVID-19 infection?" Therefore, this study evaluates the critical ventilation rates according to room size and exposure time when a susceptible person is in the same room as an infector. The analytical results were based on data obtained from 70 confirmed COVID-19 cases transmitted in confined spaces without an operational ventilation system. The results reveal that even with active ventilation (20 h(-1) air exchange rate), the critical exposure time for a susceptible person with a COVID-19 infector in a small space of 20 m(3) is less than 1 h. For other cases (different space sizes), the estimated air exchange rates for avoiding the risk of infection are generally higher than various requirements for good indoor air quality. The findings of this study will provide guidelines for determining sufficient ventilation rates to protect against the highly contagious COVID-19.en_US
dc.description.sponsorshipThe authors would like to thank KDCA for providing the valuable data. HDL is thankful for a research grant from Inha University.en_US
dc.language.isoenen_US
dc.publisherKOREAN PHYSICAL SOCen_US
dc.subjectCOVID-19en_US
dc.subjectSARS-CoV-2en_US
dc.subjectAirborne transmissionen_US
dc.subjectAir exchange rateen_US
dc.subjectVentilationen_US
dc.titleEstimate of the critical exposure time based on 70 confirmed COVID-19 casesen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume79-
dc.identifier.doi10.1007/s40042-021-00225-9-
dc.relation.page492-498-
dc.relation.journalJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.contributor.googleauthorLee, Handol-
dc.contributor.googleauthorAhn, Kang-Ho-
dc.relation.code2021006374-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidkhahn-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE