251 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author윤종헌-
dc.date.accessioned2021-12-23T04:17:28Z-
dc.date.available2021-12-23T04:17:28Z-
dc.date.issued2021-01-
dc.identifier.citationAPPLIED SCIENCES-BASEL, v. 11, No. 2, Article no. 496, 12ppen_US
dc.identifier.issn2076-3417-
dc.identifier.urihttps://www.mdpi.com/2076-3417/11/2/496-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/167016-
dc.description.abstractThis paper mainly examines the fixation performances of the cephalomedullary nail for the incidence of intertrochanteric (IT) fracture to guide the appropriate fixations with respect to the bone density in terms of a biomechanical perspective. It is substantially important to guide which types of fixation are applied during the operation since it tends to induce the backout or migration of the helical blade and screw according to weight and bone density. Biomedical polyurethane (PUR) foam blocks for simulating human bone are adopted with two grades of densities to simulate a normal person and an elderly person who has osteoporosis. Tensile and compression tests are conducted to analyze the tensile-compression anisotropy of PUR foams. Pull-out performances of screw and helical blades are evaluated from experimental perspectives, which are supported by comparison with the results of finite element method analysis. The clamping force of the screw is higher than the helical blade, about 177% in normal foam density and 198% in low foam density. After physical evaluation of the critical pull-out fixation force of screw and helical blade, we have suggested that stable fixation is guaranteed when the pull-out force is larger than projected force.en_US
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.subjectcephalomedullaryen_US
dc.subjectpull-out forceen_US
dc.subjectfemur boneen_US
dc.subjecthelical bladeen_US
dc.subjectscrewen_US
dc.subjectpolyurethane (PUR) foamen_US
dc.titleComparative Pull-Out Performances of Cephalomedullary Nail with Screw and Helical Blade According to Femur Bone Densitiesen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume11-
dc.identifier.doi10.3390/app11020496-
dc.relation.page1-12-
dc.relation.journalAPPLIED SCIENCES-BASEL-
dc.contributor.googleauthorPark, Young-Chang-
dc.contributor.googleauthorChae, Dong-Sik-
dc.contributor.googleauthorKang, Kyung-Yil-
dc.contributor.googleauthorDing, Yao-
dc.contributor.googleauthorPark, Sung-Jun-
dc.contributor.googleauthorYoon, Jonghun-
dc.relation.code2021004533-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidjyoon-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE