Full metadata record

DC FieldValueLanguage
dc.contributor.author이방욱-
dc.date.accessioned2021-12-23T02:02:29Z-
dc.date.available2021-12-23T02:02:29Z-
dc.date.issued2021-04-
dc.identifier.citationENERGIES, v. 14, No. 8, Article no. 2296, 18ppen_US
dc.identifier.issn1996-1073-
dc.identifier.urihttps://www.mdpi.com/1996-1073/14/8/2296-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/166822-
dc.description.abstractA converter valve unit, which converts Alternating Current (AC) to Directing Current (DC) and DC to AC, is one of the key elements of high voltage direct current (HVDC) transmission. The insulation design of a converter valve unit should be considered for air clearance according to the DC superimposed overvoltage and the insulator that maintains the insulation performance and the corona shield to suppress DC corona discharge. There is no prescribed standard for the insulation design of a converter valve unit. Moreover, insulation performance under an applied DC voltage has not yet been thoroughly investigated. Therefore, it is necessary to study the insulation design method of the converter valve unit. In this paper, consideration of the insulation design method on a ±200 kV converter valve unit in an HVDC converter hall is performed. The finite element method (FEM) is used to simulate the 3D model. Additionally, the safety factor (SF) is applied in accordance with the dielectric test in IEC 62271-1. As a result, an insulation design process on the converter valve unit is proposed and the insulation design is carried through the design factors. It is confirmed that design factors on the air clearance, insulator and corona shield have a significant effect on a highly reliable insulation design.en_US
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.subjectconverter valveen_US
dc.subjectair clearanceen_US
dc.subjectovervoltageen_US
dc.subjectflashoveren_US
dc.subjecttriple pointen_US
dc.subjectinsulatoren_US
dc.subjectFEMen_US
dc.subjectcorona shielden_US
dc.subjectDC corona inception electric fielden_US
dc.titleConsideration of the Insulation Design Method on a ± 200 kV Converter Valve Unit in an HVDC Converter Hallen_US
dc.typeArticleen_US
dc.relation.no8-
dc.relation.volume14-
dc.identifier.doi10.3390/en14082296-
dc.relation.page1-18-
dc.relation.journalENERGIES-
dc.contributor.googleauthorBang, Seungmin-
dc.contributor.googleauthorKim, Ho-Seung-
dc.contributor.googleauthorKoo, Jae-Hong-
dc.contributor.googleauthorLee, Bang-Wook-
dc.relation.code2021002297-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDIVISION OF ELECTRICAL ENGINEERING-
dc.identifier.pidbangwook-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.