161 0

Evaluation of Hydroxychloroquine Retinopathy Using Ultra-Widefield Fundus Autofluorescence: Peripheral Findings in the Retinopathy

Title
Evaluation of Hydroxychloroquine Retinopathy Using Ultra-Widefield Fundus Autofluorescence: Peripheral Findings in the Retinopathy
Author
이병로
Keywords
RECOMMENDATIONS; CHLOROQUINE; PROGRESSION
Issue Date
2020-01
Publisher
ELSEVIER SCIENCE INC
Citation
AMERICAN JOURNAL OF OPHTHALMOLOGY, v. 209, page. 35-44
Abstract
OBJECTIVES: To investigate the application of ultra-widefield fundus autofluorescence (UWF-FAF) imaging in evaluating hydroxychloroquine (HCQ) retinopathy and to report peripheral autofluorescence findings in Asian patients with this condition. DESIGN: Retrospective case series. METHODS: Setting: institutional. Patient population: 58 eyes of 29 patients with HCQ retinopathy. Observation procedures: UWF-FAF imaging was performed, and the images were compared to conventional FAF images obtained using a confocal digital ophthalmoscope. The sensitivities of detecting retinopathy using the 2 modalities were compared. Peripheral autofluorescence findings in the eyes with HCQ retinopathy were assessed, and their association with the Humphrey visual field test results obtained using the 30-2 and full-field 120 (FF-120) protocols was analyzed. Main outcome measurements were abnormal FAF findings. RESULTS: In 41 of 58 eyes (70.7%) with HCQ retinopathy, abnormal FAF findings were noted in the retinal periphery outside the field of view of conventional FAF as hypoautofluorescent (23 eyes, 39.7%) and hyperautofluorescent (38 eyes, 65.5%) lesions. In 5 eyes (8.6%), differences were revealed between conventional FAF and UWF-FAF in detecting retinopathy. Most of the eyes with severe retinopathy showed the most extensive hypoautofluorescence in the nasal peripheral retina. The areas with abnormal FAF findings were significantly correlated with the number of unseen spots on FF-120 results and mean deviation and pattern standard deviation of the 30-2 test results (all P ˂ .001). CONCLUSIONS: Peripheral autofluorescence findings varied in eyes with HCQ retinopathy according to the severity of the retinopathy. The retinal findings with UWF-FAF were functionally correlated to visual field results. UWF-FAF may be useful for evaluating HCQ retinopathy, particularly in Asian patients. (C) 2019 Elsevier Inc. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0002939419304659?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/160963
ISSN
0002-9394; 1879-1891
DOI
10.1016/j.ajo.2019.09.008
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE