536 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정윤선-
dc.date.accessioned2021-02-23T01:14:14Z-
dc.date.available2021-02-23T01:14:14Z-
dc.date.issued2020-01-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, v. 52, no. 8, page. 1826-1833en_US
dc.identifier.issn1738-5733-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1738573319307028?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/158875-
dc.description.abstractAdministration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine. (C) 2020 Korean Nuclear Society, Published by Elsevier Korea LLC.en_US
dc.description.sponsorshipThis research was supported by a grant of the Korea Institute of Radiological and Medical Sciences (KIRAMS), funded by Ministry of Science and ICT (MSIT), Republic of Korea. (No. 50445-2019).en_US
dc.language.isoenen_US
dc.publisherKOREAN NUCLEAR SOCen_US
dc.subjectStable iodineen_US
dc.subjectPotassium iodideen_US
dc.subjectThyroid blockingen_US
dc.subjectThyroid doseen_US
dc.subjectInternal dosimetryen_US
dc.subjectICRP biokinetic modelen_US
dc.titleApplication of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blockingen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.net.2020.01.031-
dc.relation.page1-8-
dc.relation.journalNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.contributor.googleauthorKwon, Tae-Eun-
dc.contributor.googleauthorChung, Yoonsun-
dc.contributor.googleauthorHa, Wi-Ho-
dc.contributor.googleauthorJin, Young Woo-
dc.relation.code2020052249-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidychung-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE