Full metadata record

DC FieldValueLanguage
dc.contributor.author김기현-
dc.date.accessioned2020-11-30T07:54:10Z-
dc.date.available2020-11-30T07:54:10Z-
dc.date.issued2019-12-
dc.identifier.citationSEPARATION AND PURIFICATION TECHNOLOGY, v. 228, article no. 115729en_US
dc.identifier.issn1383-5866-
dc.identifier.issn1873-3794-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1383586618334105?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/156083-
dc.description.abstractThe general performance metric for sorbent is its maximum adsorption capacity in which the maximum amount of an adsorbate loadable on an adsorbent is determined from isotherms. Such a metric is useful to ascertain the maximum possible capacity obtained at high adsorbate partial pressures (e.g., > 1,000 Pa). However, this is often misleading to predict the performance of materials in real-world applications where the ambient trace pollutant levels are much lower, e.g., < 0.1 Pa. The use of such concept at such low pressure condition is also very problematic if the isotherm follows Henry's law. Overall, although such a metric is commonly reported, its utility is significantly limited for treating trace level pollutants. This study demonstrates the inadequacy of such definition based on experimental and theoretical basis. It is thus recommended that researchers must provide a complete isotherm analysis (e.g., Langmuir or Henry's law) in the 0-10 Pa pressure region as supplementary datasets in support of any bold claims that a proposed sorbent is very fit for low pollutant pressure ( < 10 Pa) air quality management (AQM) purposes. Also, if the adsorption isotherm volumetric method is used, it is suggested that the isotherms should be constructed to cover a good range of intervals over 0-10 Pa region for AQM purposes (e.g., 0, 0.001, 0.003, 0.01, 0.03, 0.1, 0.3, 1, 3, and 10 Pa). It is futher recommended, if possible, to expand such test over an extended range (e.g., 30, 100, 300, and 1000 Pa) for a facile assessment of performance on a log-log isotherm plot.en_US
dc.description.sponsorshipThis study was supported by a grant from the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (Grant No: 2016R1E1A1A01940995).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectMaximum adsorptionen_US
dc.subjectSorbentsen_US
dc.subjectCapacityen_US
dc.subjectAQMen_US
dc.subjectReal-world applicationsen_US
dc.titleIs the maximum adsorption capacity obtained at high VOC pressures (> 1000 Pa) really meaningful in real-world applications for the sorptive removal of VOCs under ambient conditions (< 1 Pa)?en_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.seppur.2019.115729-
dc.relation.page1-5-
dc.relation.journalSEPARATION AND PURIFICATION TECHNOLOGY-
dc.contributor.googleauthorSzulejko, Jan E.-
dc.contributor.googleauthorKim, Ki-Hyun-
dc.relation.code2019040935-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidkkim61-
dc.identifier.researcherIDI-8499-2018-
dc.identifier.orcidhttps://orcid.org/0000-0003-0487-4242-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE