Abstract
The primary purpose of this study is to investigate punching shear capacity of flat plate slab using high strength concrete in column. It may be much contributed to economy efficiency and structural advantages that High Strength Concrete(HSC) used for vertical member and Normal Strength Concrete(NSC) for horizontal member. Therefore, six plate flat slab specimens with HSC column and NSC slab had been made and tested with real scale. The major variables were compressive strength of concrete(fck=285, 460kgf/cm2). extended length of HSC from column face and amount of shear reinforcements. As the result of this test the maximum load and punching shear capacity of specimens is affected by extended length and shear reinforcements. RC구조물의 기둥과 같은 수직부재에는 고강도 콘크리트를 그리고 슬래브와 같은 수평부재에는 보통강도 콘크리트를 사용할 경우 경제적인 효율성은 물론 구조적인 많은 이점을 얻을 수 있을 것으로 기대왼다. 그러 나 이 경우 슬래브와 기풍의 강도 및 강성차이로 인한 뚫립전단의 위험이 있어,본 연구에서는 기둥에는 fck=460kgf/cm2의 고강도 콘크리트를, 슬래브에는 fck=285kgf/cm2의 보통강도 콘크리트를 타설한 실물 크기의 플랫 플레이트 슬래브 실험체 6개를 제작하여 뚫립전단성능을 평가하였다. 주요 실험변수는 콘크리트 압축강도, 기둥면으로부터 내민길이, 휨철근 추가에 의한 전단 보강근량이다. 실험결과 고강도 콘크리트 내 민길이와 슬래브 휨철근 추가에 의한 전단보강은 최대내력의 증가와 뚫림전단저항성능을 향상시킬 수 있으 나,최대하중 이후 실험체의 거동에는 큰 영향이 없는 것으로 나타났다.
URI
http://db.koreascholar.com/Article?code=264542https://repository.hanyang.ac.kr/handle/20.500.11754/156008
ISSN
2234-6937
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ARCHITECTURE(건축학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE