196 97

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2020-09-22T05:51:33Z-
dc.date.available2020-09-22T05:51:33Z-
dc.date.issued2019-09-
dc.identifier.citation방사선방어학회지, v. 44, no. 3, Page. 103-109en_US
dc.identifier.issn2508-1888-
dc.identifier.issn2466-2461-
dc.identifier.urihttp://jrpr.org/journal/view.php?doi=10.14407/jrpr.2019.44.3.103-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/154045-
dc.description.abstractBackground: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.en_US
dc.description.sponsorshipThis research was supported by Basic Science Research Program through the National Research Foundation of Ko -rea (NRF) funded by the Ministry of Education (NRF2016R1D1A1A09916337), and by the Nuclear Safety Research and Development (NSR&D) Program through the Korea Foundation of Nuclear Safety (KoFONS) funded by Nuclear Safety and Security Commission (NSSC) (Project Number: 1705006).en_US
dc.language.isoenen_US
dc.publisher대한방사선방어학회en_US
dc.subject4D Dose Calculationen_US
dc.subjectExtra-Phase Imageen_US
dc.subjectDeformable Image Registrationen_US
dc.subjectEx - panded Respirationen_US
dc.titleExtra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motionen_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume44-
dc.identifier.doi10.14407/jrpr.2019.44.3.103-
dc.relation.page103-109-
dc.relation.journal방사선방어학회지-
dc.contributor.googleauthorLee, Hyun Su-
dc.contributor.googleauthorChoi, Chansoo-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.contributor.googleauthorHan, Min Cheol-
dc.contributor.googleauthorYeom, Yeon Soo-
dc.contributor.googleauthorNguyen, Thang Tat-
dc.contributor.googleauthorKim, Seonghoon-
dc.contributor.googleauthorChoi, Sang Hyoun-
dc.contributor.googleauthorLee, Soon Sung-
dc.contributor.googleauthorKim, Jina-
dc.relation.code2019035086-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE