Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study

Title
Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study
Author
황규태
Keywords
Acetabular revision; Jumbo cup; Migration; Wear
Issue Date
2019-08
Publisher
SPRINGER
Citation
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v. 139, no. 8, Page. 1149-1160
Abstract
IntroductionAcetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up.Materials and methodsEighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan-Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Rontgen-Analyse software.ResultsThe mean preoperative HHS of 53 had improved to 77 at the final follow-up (p=0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16years according to the Kaplan-Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p=0.045). The mean total migration was 1.52mm, and the mean total wear was 0.98mm. There was a positive correlation between total migration and total wear (p=0.023; Spearman's rho=0.388). The mean wear rate of the patients with the cup inclination angle<50 degrees was significantly lower than those with the cup inclination angle>50 degrees (p=0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery.ConclusionPress-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle<50 degrees may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.
URI
https://link.springer.com/article/10.1007/s00402-019-03214-7https://repository.hanyang.ac.kr/handle/20.500.11754/153511
ISSN
0936-8051; 1434-3916
DOI
10.1007/s00402-019-03214-7
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE