275 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2020-08-19T01:33:40Z-
dc.date.available2020-08-19T01:33:40Z-
dc.date.issued2019-07-
dc.identifier.citationRADIATION MEASUREMENTS , v. 126, article no. 106126en_US
dc.identifier.issn1350-4487-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1350448718307303?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/152333-
dc.description.abstractIn case of a radiation emergency, thermoluminescence (TL) and optically stimulated luminescence (OSL) measurements from materials in a mobile phone have been developed to enable classification of exposed individuals within a short period of time. A reconstructed dose from a mobile phone does not, however, correspond directly to a human body dose. Therefore, several studies were tried to convert a phone dose to a human body dose. Because of the difficulty in obtaining conversion factors experimentally, Monte Carlo simulations have been carried out using human phantoms for various accident situations. In recent years phantoms made of mesh have been developed to solve some problems in traditional voxel phantoms such as limited posture. In the present study, simulations using the GEANT4 computer code were performed to obtain conversion factors using mesh phantoms. The geometry of a mobile phone was designed, reflecting latest structures, and a display glass was selected as a dosimetric material due to its wide detection area with a high radiation sensitivity. Four different positions (chest, hip, thigh, and hand) of a mobile phone on the phantom were considered. In addition, six exposure conditions of anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), isotropic (ISO), and rotational (ROT) exposure geometries and three different postures of standing, kneeling, and squatting were selected to reflect actual working situations. Three commonly used radiation sources (Iridium-192, Cesium-137, and Cobalt-60) were applied.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (Ministry of Science and ICT) (No.2017M2A8A4015255) and the Nuclear Safety Research Program through the Korea Foundation Of Nuclear Safety (KoFONS) using the financial resource granted by the Nuclear Safety and Security Commission (NSSC) of the Republic of Korea (No.1803014).en_US
dc.language.isoenen_US
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_US
dc.subjectThermoluminescence (TL)en_US
dc.subjectOptically stimulated luminescence (OSL)en_US
dc.subjectDisplay glass of a mobile phoneen_US
dc.subjectMesh phantomen_US
dc.subjectRetrospective dosimteryen_US
dc.titleA study on dose conversion from a material to human body using mesh phantom for retrospective dosimetryen_US
dc.typeArticleen_US
dc.relation.volume126-
dc.identifier.doi10.1016/j.radmeas.2019.106126-
dc.relation.page1-5-
dc.relation.journalRADIATION MEASUREMENTS-
dc.contributor.googleauthorKim, Min Chae-
dc.contributor.googleauthorKim, Hyoungtaek-
dc.contributor.googleauthorHan, Haegin-
dc.contributor.googleauthorLee, Jungil-
dc.contributor.googleauthorLee, Seung Kyu-
dc.contributor.googleauthorChang, Insu-
dc.contributor.googleauthorKim, Jang-Lyul-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.relation.code2019001517-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE