Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동립 | - |
dc.date.accessioned | 2019-12-09T17:46:43Z | - |
dc.date.available | 2019-12-09T17:46:43Z | - |
dc.date.issued | 2018-10 | - |
dc.identifier.citation | ENERGY CONVERSION AND MANAGEMENT, v. 174, page. 218-226 | en_US |
dc.identifier.issn | 0196-8904 | - |
dc.identifier.issn | 1879-2227 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0196890418308963?via%3Dihub | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/120303 | - |
dc.description.abstract | The thermal performance of a plate fin heat sink was investigated as a function of the location of multiple heat sources to minimize the thermal interference effect. Numerical analysis was performed under forced-convection conditions to design a cooling system for a high-power heat source. The thermal behaviors of the heat sink and surrounding air were simulated. We also investigated the thermal performances of various base thicknesses under local heat flux conditions to determine the optimal heat sink base thickness using the width of the heat source and conduction coefficient of the heat sink. The optimal location was determined by investigating the effects of the Reynolds number, thermal conductivity of the heat sink, heat transfer rate ratio for multiple heat sources, and width of the heat source. An installation guideline of the plate fin heat sink was prepared to help users avoid the thermal interference effect depending on the width of their heat source. By applying a correlation equation to obtain the optimal location where the maximal temperature of the heat source is minimized, the thermal resistance was decreased by up to 30%. | en_US |
dc.description.sponsorship | This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. 20162010103830, No. 20184010201710). | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | en_US |
dc.subject | Electronic cooling | en_US |
dc.subject | Heat sink | en_US |
dc.subject | Forced convection | en_US |
dc.subject | Multiple heat source | en_US |
dc.subject | Thermal interference | en_US |
dc.title | Minimizing thermal interference effects of multiple heat sources for effective cooling of power conversion electronics | en_US |
dc.type | Article | en_US |
dc.relation.volume | 174 | - |
dc.identifier.doi | 10.1016/j.enconman.2018.08.047 | - |
dc.relation.page | 218-226 | - |
dc.relation.journal | ENERGY CONVERSION AND MANAGEMENT | - |
dc.contributor.googleauthor | Yoon, Youngchan | - |
dc.contributor.googleauthor | Hyeon, Seounghwan | - |
dc.contributor.googleauthor | Kim, Dong Rip | - |
dc.contributor.googleauthor | Lee, Kwan-Soo | - |
dc.relation.code | 2018005580 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DIVISION OF MECHANICAL ENGINEERING | - |
dc.identifier.pid | dongrip | - |
dc.identifier.orcid | https://orcid.org/0000-0001-6398-9483 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.