183 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김동립-
dc.date.accessioned2019-12-09T17:46:43Z-
dc.date.available2019-12-09T17:46:43Z-
dc.date.issued2018-10-
dc.identifier.citationENERGY CONVERSION AND MANAGEMENT, v. 174, page. 218-226en_US
dc.identifier.issn0196-8904-
dc.identifier.issn1879-2227-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0196890418308963?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/120303-
dc.description.abstractThe thermal performance of a plate fin heat sink was investigated as a function of the location of multiple heat sources to minimize the thermal interference effect. Numerical analysis was performed under forced-convection conditions to design a cooling system for a high-power heat source. The thermal behaviors of the heat sink and surrounding air were simulated. We also investigated the thermal performances of various base thicknesses under local heat flux conditions to determine the optimal heat sink base thickness using the width of the heat source and conduction coefficient of the heat sink. The optimal location was determined by investigating the effects of the Reynolds number, thermal conductivity of the heat sink, heat transfer rate ratio for multiple heat sources, and width of the heat source. An installation guideline of the plate fin heat sink was prepared to help users avoid the thermal interference effect depending on the width of their heat source. By applying a correlation equation to obtain the optimal location where the maximal temperature of the heat source is minimized, the thermal resistance was decreased by up to 30%.en_US
dc.description.sponsorshipThis work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. 20162010103830, No. 20184010201710).en_US
dc.language.isoen_USen_US
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_US
dc.subjectElectronic coolingen_US
dc.subjectHeat sinken_US
dc.subjectForced convectionen_US
dc.subjectMultiple heat sourceen_US
dc.subjectThermal interferenceen_US
dc.titleMinimizing thermal interference effects of multiple heat sources for effective cooling of power conversion electronicsen_US
dc.typeArticleen_US
dc.relation.volume174-
dc.identifier.doi10.1016/j.enconman.2018.08.047-
dc.relation.page218-226-
dc.relation.journalENERGY CONVERSION AND MANAGEMENT-
dc.contributor.googleauthorYoon, Youngchan-
dc.contributor.googleauthorHyeon, Seounghwan-
dc.contributor.googleauthorKim, Dong Rip-
dc.contributor.googleauthorLee, Kwan-Soo-
dc.relation.code2018005580-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.piddongrip-
dc.identifier.orcidhttps://orcid.org/0000-0001-6398-9483-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.