330 165

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2019-12-08T00:37:56Z-
dc.date.available2019-12-08T00:37:56Z-
dc.date.issued2018-05-
dc.identifier.citationENERGIES, v. 11, no. 6, Article no. 1377en_US
dc.identifier.issn1996-1073-
dc.identifier.urihttps://www.mdpi.com/1996-1073/11/6/1377-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/118566-
dc.description.abstractThe main purpose of this study is to evaluate the applicability of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) in six typical cities in China. The six cities are located in different climatic zones in China and are selected because they are comparable owing to the outdoor air conditions. Many studies have shown that the annual operating energy consumption of LD-IDECOAS is nearly half compared with the conventional variable air volume (VAV) system. Because the climate characteristics of the six selected cities were different, the appropriate mode of operation of the LD-IDECAOS was applied to each studied city, and energy simulations were performed. Based on the design conditions of each region, the required cooling and heating loads were calculated for office buildings using transient system simulations (TRNSYS) 17, and the performance of the LD-IDECOAS and its energy consumption were simulated with a commercial engineering equation solver (EES) program. Depending on the climate characteristics of each city, adequate modifications were evaluated with simulations in terms of energy consumption. The proposed system was compared with the VAV system and the evaporative cooling assisted 100% outdoor air-conditioning system (IDECOAS) for detailed simulation results in the effort to evaluate the energy-saving potential. Finally, the results show that the proposed system saves considerable energy over conventional VAV systems and, in summer, the applications save even more energy than IDECOAS. However, there is a slight difference between the different geographical regions in terms of the annual operating energy consumption. In summary, the proposed system can yield significant energy-saving benefits in hot and humid regions whereas, in dry regions, the proposed system is more applicable in the summer. Consequently, LD-IDECOAS can be adopted for different climatic zones as a heating, ventilating, and air-conditioning (HVAC) system by introducing 100% outdoor air.en_US
dc.description.sponsorshipThis work was supported by the Korean Agency for Infrastructure Technology Advancement (KAIA) grants (18CTAP-C116268-03, and 18CTAP-C141826-01), and the Korea Institute of Energy Technology Evaluation and Planning (KETEP) (No. 20164010200860).en_US
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.subjectliquid desiccant systemen_US
dc.subjectevaporative cooling systemen_US
dc.subject100% outdoor air systemen_US
dc.subjectenergy simulationen_US
dc.subjectnon-vapor compression air-conditioning systemen_US
dc.titleEnergy Performance of Liquid Desiccant and Evaporative Cooling-Assisted 100% Outdoor Air Systems under Various Climatic Conditionsen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume11-
dc.identifier.doi10.3390/en11061377-
dc.relation.page1-22-
dc.relation.journalENERGIES-
dc.contributor.googleauthorLi, Shiying-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2018005894-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
dc.identifier.researcherIDK-6463-2017-
dc.identifier.orcidhttp://orcid.org/0000-0002-5391-3298-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE