341 137

Full metadata record

DC FieldValueLanguage
dc.contributor.author장경영-
dc.date.accessioned2019-12-03T04:34:35Z-
dc.date.available2019-12-03T04:34:35Z-
dc.date.issued2017-12-
dc.identifier.citationRESEARCH IN NONDESTRUCTIVE EVALUATION, v. 28, no. 4, page. 211-225en_US
dc.identifier.issn0934-9847-
dc.identifier.issn1432-2110-
dc.identifier.urihttps://www.tandfonline.com/doi/full/10.1080/09349847.2016.1174322-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/116778-
dc.description.abstractThe ultrasonic nonlinear parameter is measured from the amplitudes of the harmonic frequency components generated during the propagation of ultrasonic waves in a material. There are two definitions for this parameter: absolute and relative. The absolute parameter is defined by the displacement amplitude; however, it is difficult to measure because of the very small displacement amplitude of the harmonic components. Conversely, the relative parameter is defined by the amplitude of the detected signal, regardless of displacement. Many researchers use the relative parameter because it is easier to measure, although it is only available for a relative comparison of different materials. However, it has not yet been verified that the ratio of the relative parameters between two materials is identical to that of the absolute parameters. In this study, we make it clear that the ratio of the relative parameters is inherently not identical to that of the absolute parameters, but that they can be identical to each other by compensating for material-dependent differences, such as detection-sensitivity and wavenumber. For verification, the absolute and relative parameters were measured for two different materials. The results showed that the ratios of absolute and relative parameters were in good agreement after compensation.en_US
dc.description.sponsorshipThis research was supported by the Nuclear Power Research and Development Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (NRF-2013M2A2A9043241).en_US
dc.language.isoen_USen_US
dc.publisherTAYLOR & FRANCIS INCen_US
dc.subjectAl6061-T6en_US
dc.subjectabsolute parameteren_US
dc.subjectfused silicaen_US
dc.subjectrelative parameteren_US
dc.subjectultrasonic nonlinear parameteren_US
dc.titleAbsolute Measurement and Relative Measurement of Ultrasonic Nonlinear Parametersen_US
dc.typeArticleen_US
dc.relation.no4-
dc.relation.volume28-
dc.identifier.doi10.1080/09349847.2016.1174322-
dc.relation.page211-225-
dc.relation.journalRESEARCH IN NONDESTRUCTIVE EVALUATION-
dc.contributor.googleauthorKim, Jongbeom-
dc.contributor.googleauthorSong, Dong-Gi-
dc.contributor.googleauthorJhang, Kyung-Young-
dc.relation.code2017002436-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.pidkyjhang-
dc.identifier.orcidhttp://orcid.org/0000-0001-5168-2361-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE