Full metadata record

DC FieldValueLanguage
dc.contributor.author류두열-
dc.date.accessioned2019-12-02T21:01:03Z-
dc.date.available2019-12-02T21:01:03Z-
dc.date.issued2017-12-
dc.identifier.citationCONSTRUCTION AND BUILDING MATERIALS, v. 157, page. 498-508en_US
dc.identifier.issn0950-0618-
dc.identifier.issn1879-0526-
dc.identifier.urihttps://www.sciencedirect.com/science/article/abs/pii/S0950061817319219?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/116539-
dc.description.abstractThis paper aims to investigate the influence of exposure to cryogenic temperatures using liquid nitrogen on the mechanical properties of normal concrete (NC) and ultra-high-performance fiber-reinforced concrete (UHPFRC), which is commercially available. This research was carried out to examine the feasibility of using UHPFRC for a liquefied natural gas storage tank. For this, both compressive and direct tensile tests were performed at three different testing conditions: ambient temperature, cryogenic temperature (-170 degrees C), and recovered ambient temperature after experiencing the cryogenic temperature. The test results showed that the compressive strengths of both NC and UHPFRC were noticeably increased at the cryogenic temperature compared with those at ambient temperature. However, there was no improvement in the tensile strength of NC at the cryogenic temperature, and its tensile strength was deteriorated after exposure to the cryogenic temperature. In contrast with NC, the tensile performance of UHPFRC significantly increased, including improvements in strength, post-cracking stiffness, and energy absorption capacity. Given the superior mechanical properties, it was concluded that UHPFRC is suitable for liquefied natural gas storage tanks.en_US
dc.description.sponsorshipThis work was supported by a grant from 2016 University Cooperation Research Project funded by Korea Gas Corporation.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCI LTDen_US
dc.subjectUltra-high-performance fiber-reinforced concreteen_US
dc.subjectNormal concreteen_US
dc.subjectMechanical performanceen_US
dc.subjectCryogenic temperatureen_US
dc.subjectLNG storage tanken_US
dc.titleMechanical properties of ultra-high-performance fiber-reinforced concrete at cryogenic temperaturesen_US
dc.typeArticleen_US
dc.relation.volume157-
dc.identifier.doi10.1016/j.conbuildmat.2017.09.099-
dc.relation.page498-508-
dc.relation.journalCONSTRUCTION AND BUILDING MATERIALS-
dc.contributor.googleauthorKim, Min-Jae-
dc.contributor.googleauthorKim, Soonho-
dc.contributor.googleauthorLee, Seul-Kee-
dc.contributor.googleauthorKim, Jun-Hwi-
dc.contributor.googleauthorLee, Kangwon-
dc.contributor.googleauthorYoo, Doo-Yeol-
dc.relation.code2017006317-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.piddyyoo-
dc.identifier.orcidhttp://orcid.org/0000-0003-2814-5482-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE