dc.description.abstractThe main purpose of this study was to evaluate the cooling performances of two different types of cross flow indirect evaporative coolers (IECs) operated in two different operation modes: general and regenerative. The cooling performances of the IECs were tested in each operation mode in an environmental chamber. In the general mode, the secondary air stream passing through the wet channels was the return air from the conditioned zone; whereas, in the regenerative mode, a portion of the primary air leaving the dry channels was redirected to the secondary channels. The IEC performances were measured under constant primary air inlet temperature and humidity ratio with variations of the primary airflow. As indexes of the IEC performance, the wet-bulb effectiveness and cooling capacity of both IECs in each operation mode were estimated based on the measurement data. The experimental results revealed that, in the general operation mode, both IECs exhibited higher sensible cooling performances in terms of wet bulb effectiveness than in the regenerative mode in a 100% outdoor air system application. (C) 2017 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by a National Research Foundation (NRF) Grant (No. 2015R1A2A1A05001726) and the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. 20164010200860).en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCI LTDen_US
dc.subjectIndirect evaporative cooling systemen_US
dc.subjectCross-flow indirect evaporative cooleren_US
dc.subjectDew-point evaporative cooleren_US
dc.subjectEnergy efficiencyen_US
dc.titleCooling performance measurement of two cross-flow indirect evaporative coolers in general and regenerative operation modesen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume195-
dc.identifier.doi10.1016/j.apenergy.2017.03.053-
dc.relation.page268-277-
dc.relation.journalAPPLIED ENERGY-
dc.contributor.googleauthorKim, Hui-Jeong-
dc.contributor.googleauthorHam, Sang-Woo-
dc.contributor.googleauthorYoon, Dong-Seob-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2017002164-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE