dc.identifier.citationApplied Thermal Engineering, v. 157, UNSP 113712en_US
dc.identifier.issn1359-4311-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1359431119302273?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/111683-
dc.description.abstractMulti-split air-source heat pumps (ASHPs) have been widely used for both heating and cooling. An electric expansion valve (EEV) is frequently positioned in the indoor unit (IDU), leading to an increase in the two-phase flow noise of the refrigerant. In this study, we experimentally investigated the two-phase flow patterns and flow-induced noise of R410A refrigerant near the EEV in an IDU during the heating cycle of a multi-split ASHP with four IDUs. The flow-induced noise and two-phase flow patterns of horizontal and vertical pipe layouts near the EEV were simultaneously measured under a transient operation condition of temperature (24–38 °C), pressure (1.7–2.7 MPa), and mass flowrate (6.2–41.9 kg/h). The big noise near the EEV was generated for an intermittent flow and a churn/slug flow pattern at the EEV inlet for both horizontal and vertical pipe layouts, respectively. Unlike refrigerators and cooling air-conditioners, a vertical pipe layout has two-phase flow patterns that are advantageous for noise reduction near the EEV because of the high operating mass flux and pressure for R410A of a heating cycle of a multi-split ASHP. The two-phase flow-induced noise of the refrigerant near the EEV was strongly affected by the flow patterns at the EEV's inlet and outlet. The present study indicates that the flow patterns affected by pipe layout, phase properties, and operating conditions should be considered as one of the important factors in designing a refrigerant system of reduced noise.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (Ministry of Science, ICT, and Future Planning) (No. 2016R1A2B3009541) and the Korea Institute of Energy Technology Evaluation and Planning (KETEP) granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea (No. 20184010201710).en_US
dc.language.isoenen_US
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_US
dc.subjectTwo-phase flowen_US
dc.subjectRefrigerant flow-induced noiseen_US
dc.subjectR410Aen_US
dc.subjectElectric expansion valveen_US
dc.subjectMulti-split air-source heat pumpen_US
dc.titleFlow visualization and noise measurement of R410A two-phase flow near electric expansion valve for heating cycle of multi-split air-source heat pumpen_US
dc.typeArticleen_US
dc.relation.volume157-
dc.identifier.doi10.1016/j.applthermaleng.2019.113712-
dc.relation.page1-10-
dc.relation.journalApplied Thermal Engineering-
dc.contributor.googleauthorKim, Gangjune-
dc.contributor.googleauthorLee, Jaehong-
dc.contributor.googleauthorPark, Junhong-
dc.contributor.googleauthorSong, Simon-
dc.relation.code2019010774-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.pidsimonsong-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE