349 219

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2019-08-13T05:38:41Z-
dc.date.available2019-08-13T05:38:41Z-
dc.date.issued2019-03-
dc.identifier.citation방사선방어학회지, v. 44, NO 1, Page. 1-7en_US
dc.identifier.issn2508-1888-
dc.identifier.issn2466-2461-
dc.identifier.urihttp://jrpr.org/journal/view.php?doi=10.14407/jrpr.2019.44.1.1-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/108531-
dc.description.abstractBackground: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( ˂108 protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.en_US
dc.description.sponsorshipThis work was supported by the Nuclear Safety Research and Development (NSR&D) Program through the Korea Foundation of Nuclear Safety (KoFONS) funded by the Nu-clear Safety and Security Commission (NSSC) (Project Num-ber: 1705006).en_US
dc.language.isoenen_US
dc.publisher대한방사선방어학회en_US
dc.subjectProton therapyen_US
dc.subjectProton beam monitoringen_US
dc.subjectPrompt gammaen_US
dc.subjectBeam range verificationen_US
dc.subjectPrompt gamma statisticsen_US
dc.titleImprovement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Studyen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume44-
dc.identifier.doi10.14407/jrpr.2019.44.1.1-
dc.relation.page1-7-
dc.relation.journal방사선방어학회지-
dc.contributor.googleauthorKim, Sung Hun-
dc.contributor.googleauthorPark, Jong Hoon-
dc.contributor.googleauthorKu, Youngmo-
dc.contributor.googleauthorLee, Hyun Su-
dc.contributor.googleauthorKim, Young-su-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.contributor.googleauthorJeong, Jong Hwi-
dc.relation.code2019035086-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE