300 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용균-
dc.date.accessioned2019-01-09T04:51:42Z-
dc.date.available2019-01-09T04:51:42Z-
dc.date.issued2016-10-
dc.identifier.citation2016 Transactions of the Korean Nuclear Society Autumn Meeting, Page. 1-3en_US
dc.identifier.urihttps://www.kns.org/files/pre_paper/36/16A-059%EC%9D%B4%EC%B2%A0%ED%98%B8.pdf-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/81162-
dc.description.abstractPlastic scintillators are based on organic fluorite. They have many advantages such as fast rise and decay time, high optical transmission, ease of manufacturing, low cost, and large available size. For these reasons they are widely used for particle identification. Also, protection of people against a variety of threats (such as nuclear, radiological, and explosive) represents a true challenge along with the continuing development of science and technology. The plastic scintillator is widely used in various devise, which serves for nuclear, photonics, quantum, and high-energy physics. The plastic scintillator is probably the most widely used organic detector, and polystyrene is one of the most widely used materials in the making of the plastic scintillator detector. Thus, a styrene monomer as a solvent was used to fabricate the plastic scintillator by using high temperature polymerization reaction, and then the emission wavelength and the decay times for different energy depositions were measured by using the fabricated plastic scintillator. A plastic scintillator was fabricated to measure decay time for different energy depositions using the high temperature polymerization. Emission wavelength was measured of 426.05 nm to confirm a scintillator property using the spectrophotometer. Four gamma-ray sources (Cs-137, Co-60, Na-22, and Ba-133) were used to evaluate effect for decay time of different energy depositions. The average decay time of the fabricated plastic scintillator was measured to approximately 4.72 ns slightly higher more than commercial plastic scintillator. In future, light output and linearity will be measured to evaluate other property compared with the commercial scintillatoren_US
dc.language.isoenen_US
dc.publisher한국원자력학회en_US
dc.titleDecay Time Measurement for Different Energy Depositions of Plastic Scintillator Fabricated by High Temperature Polymerization Reactionen_US
dc.typeArticleen_US
dc.relation.page1-3-
dc.contributor.googleauthorLee, Cheol Ho-
dc.contributor.googleauthorSon, Jaebum-
dc.contributor.googleauthorLee, Sangmin-
dc.contributor.googleauthorKim, Tae Hoon-
dc.contributor.googleauthorKim, Yong-Kyun-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidykkim4-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles