233 141

Full metadata record

DC FieldValueLanguage
dc.contributor.author임창환-
dc.date.accessioned2018-11-12T05:22:20Z-
dc.date.available2018-11-12T05:22:20Z-
dc.date.issued2016-09-
dc.identifier.citationSENSORS, v. 16, NO. 9, Page. 1-10en_US
dc.identifier.issn1424-8220-
dc.identifier.urihttps://www.mdpi.com/1424-8220/16/9/1494-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/80325-
dc.description.abstractRespiratory rate (RR) is a useful vital sign that can not only provide auxiliary information on physiological changes within the human body, but also indicate early symptoms of various diseases. Recently, methods for the estimation of RR from photoplethysmography (PPG) have attracted increased interest, because PPG can be readily recorded using wearable sensors such as smart watches and smart bands. In the present study, we propose a new method for the fast and robust real-time estimation of RR using an adaptive infinite impulse response (IIR) notch filter, which has not yet been applied to the PPG-based estimation of RR. In our offline simulation study, the performance of the proposed method was compared to that of recently developed RR estimation methods called an adaptive lattice-type RR estimator and a Smart Fusion. The results of the simulation study show that the proposed method could not only estimate RR more quickly and more accurately than the conventional methods, but also is most suitable for online RR monitoring systems, as it does not use any overlapping moving windows that require increased computational costs. In order to demonstrate the practical applicability of the proposed method, an online RR estimation system was implemented.en_US
dc.description.sponsorshipThis research was supported by the National Research Foundation of Korea (NRF) grants funded by the Ministry of Science, ICT & Future Planning (MSIP) (NRF-2015M3C7A1065052 and 2015R1A2A1A15054662).en_US
dc.language.isoenen_US
dc.publisherMDPI AGen_US
dc.subjectrespiratory rateen_US
dc.subjectphotoplethysmographyen_US
dc.subjectadaptive IIR notch filteren_US
dc.titleFast and Robust Real-Time Estimation of Respiratory Rate from Photoplethysmographyen_US
dc.typeArticleen_US
dc.relation.no9-
dc.relation.volume16-
dc.identifier.doi10.3390/s16091494-
dc.relation.page1-10-
dc.relation.journalSENSORS-
dc.contributor.googleauthorKim, Hodam-
dc.contributor.googleauthorKim, Jeong-Youn-
dc.contributor.googleauthorIm, Chang-Hwan-
dc.relation.code2016007221-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING-
dc.identifier.pidich-
dc.identifier.orcidhttp://orcid.org/0000-0003-3795-3318-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE