386 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2018-09-28T00:42:55Z-
dc.date.available2018-09-28T00:42:55Z-
dc.date.issued2016-08-
dc.identifier.citationENERGY AND BUILDINGS, v. 126, Page. 447-454en_US
dc.identifier.issn0378-7788-
dc.identifier.issn1872-6178-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0378778816304194?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/76220-
dc.description.abstractThe main purpose of this research was to propose a practical correlation for predicting the dehumidification effectiveness of a liquid desiccant (LD) system. The experimental data were collected during the operation of a typical liquid desiccant dehumidification unit. A lithium chloride (LiCI) solution was.used as the liquid desiccant solution. The 2000 m3/h LD unit was installed in a real building, and the variation of the dehumidification effectiveness values was monitored under various operating conditions. The data were statistically analyzed by the response surface methodology (REM), and the impact of each system operation parameter on the dehumidification effectiveness was estimated quantitatively. Six operating parameters - the mass flow rate of process air, the mass flow rate of the desiccant solution, the dry-bulb temperature and the humidity ratio of the inlet air, and the inlet temperature and concentration of the desiccant solution - significantly affected the dehumidification performance of the LD unit. Consequently, a simplified linear equation model was derived as a function of the operation parameters that significantly impacted the dehumidification effectiveness. The proposed model was verified by comparison with existing models. (C) 2016 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by a National Research Foundation of Korea (NRF) grant funded by the Korean Government (No.2015R1A2A1A05001726).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE SAen_US
dc.subjectLiquid desiccanten_US
dc.subjectDehumidification effectivenessen_US
dc.subjectAbsorberen_US
dc.subjectDesiccant coolingen_US
dc.titleEmpirical model for predicting the dehumidification effectiveness of a liquid desiccant systemen_US
dc.typeArticleen_US
dc.relation.volume126-
dc.identifier.doi10.1016/j.enbuild.2016.05.050-
dc.relation.page447-454-
dc.relation.journalENERGY AND BUILDINGS-
dc.contributor.googleauthorPark, Joon-Young-
dc.contributor.googleauthorYoon, Dong-Seop-
dc.contributor.googleauthorLee, Sung-Joon-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2016007202-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE