222 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김정은-
dc.date.accessioned2018-04-16T00:58:31Z-
dc.date.available2018-04-16T00:58:31Z-
dc.date.issued2012-01-
dc.identifier.citationSKIN RESEARCH AND TECHNOLOGY, 2012, 18(3), P.347-355en_US
dc.identifier.issn0909-752X-
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/abs/10.1111/j.1600-0846.2011.00575.x-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/67206-
dc.description.abstractBackgroundThere are several available treatments for vitiligo, but measurement of their therapeutic efficacy is not standardized and is somewhat arbitrary based largely on the global impression of the overall response. The purpose of this study was to develop a quantitative method for evaluating the treatment response of vitiligo measuring changes in area using digital image analysis. We applied this parametric model to the evaluation of efficacy of the 308 nm excimer laser.MethodsThis study was a retrospective study, designed as a before and after trial with a single arm. A total of 18 patients were enrolled who had been treated with a 308 nm excimer laser as monotherapy twice a week for 20 sessions. The repigmentation percentage was calculated by measuring changes in area before and after treatment using digital image analysis and graded on a five‐point ordinal scale [global assessment scale (GAS)]. GAS was also measured by physician and patient for comparison with our estimates. Additional GASs were also measured by four different evaluators for inter‐rater variability.ResultsThe mean repigmentation percentage after treatment was 45.3% (range, 0.7–100%). The changes in area after treatment were statistically significant (P < 0.05). A substantial agreement of outcomes was observed between physicians and digital image analysis (κw = 0.78), but lower agreement was observed between patients and digital image analysis (κw = 0.49). The inter‐rater variability for GAS was substantially low (Krippendorff's α = 79.3%).ConclusionMeasurement of changes in area using digital image analysis could be used as a quantitative method in evaluating efficacy of treatment for vitiligo. Because vitiligo lesions can occur in any location with various shapes and sizes, digital image analysis would be a more objective method for measuring treatment response than a GAS.en_US
dc.language.isoenen_US
dc.publisherBlackwell Publishing Ltden_US
dc.subjectareaen_US
dc.subjectdigital image analysisen_US
dc.subjectexcimer laseren_US
dc.subjectglobal assessment scaleen_US
dc.subjectrepigmentation percentageen_US
dc.subjectvitiligoen_US
dc.titleQuantitative method for measuring therapeutic efficacy of the 308 nm excimer laser for vitiligoen_US
dc.typeArticleen_US
dc.relation.volume18-
dc.identifier.doi10.1111/j.1600-0846.2011.00575.x-
dc.relation.page347-355-
dc.relation.journalSKIN RESEARCH AND TECHNOLOGY-
dc.contributor.googleauthorOh, T. S.-
dc.contributor.googleauthorLee, O.-
dc.contributor.googleauthorKim, J. E.-
dc.contributor.googleauthorSon, S. W.-
dc.contributor.googleauthorOh, C. H.-
dc.relation.code2012208701-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.piddermakim-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE