Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권오경 | - |
dc.date.accessioned | 2018-03-28T07:59:25Z | - |
dc.date.available | 2018-03-28T07:59:25Z | - |
dc.date.issued | 2013-10 | - |
dc.identifier.citation | Biomedical Circuits and Systems Conference (BioCAS), 2013, P.170-173 | en_US |
dc.identifier.isbn | 978-1-4799-1471-5 | - |
dc.identifier.isbn | 978-1-4799-1469-2 | - |
dc.identifier.issn | 2163-4025 | - |
dc.identifier.uri | http://ieeexplore.ieee.org/abstract/document/6679666/ | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11754/53382 | - |
dc.description.abstract | We propose an electromyogram (EMG) readout front-end with an automatic gain controller (AGC) for a human-computer interface (HCI). The proposed AGC adaptively controls voltage gain depending on the amplitude of the extracted EMG signal, which is varied according to the number of muscle fibers and the surface condition of the skin. Furthermore, the AGC alleviates the resolution requirement of an analog-digital converter (ADC) by fitting the maximum amplitude of the EMG signal to the full input range of the ADC. In order to obtain the wide-gain range, two variable gain amplifiers (VGAs) are used in the AGC. The voltage gain of the AGC is adjusted from 0 to 48.2 dB. A digital gain controller is employed to reduce the power consumption of the AGC. The calculated power efficiency of the AGC is 6.51 dB/μW. The proposed readout front-end is fabricated by using a 0.18 μm CMOS process technology and dissipates 19 μW at the supply voltage of 1.5 V. | en_US |
dc.description.sponsorship | This work was supported by the BK 21 Plus. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IEEE | en_US |
dc.subject | Components | en_US |
dc.subject | Circuits | en_US |
dc.subject | Devices and Systems | en_US |
dc.subject | Electromyography | en_US |
dc.subject | Gain | en_US |
dc.subject | Automatic generation control | en_US |
dc.subject | Capacitors | en_US |
dc.subject | Human computer interaction | en_US |
dc.subject | Gain control | en_US |
dc.subject | Envelope detectors | en_US |
dc.title | An EMG Readout Front-End with Automatic Gain Controller for Human-Computer Interface | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1109/BioCAS.2013.6679666 | - |
dc.relation.page | 170-173 | - |
dc.contributor.googleauthor | Seol, Hyeon-Cheon | - |
dc.contributor.googleauthor | Kwon, Young-Cheon | - |
dc.contributor.googleauthor | Hong, Seong-Kwan | - |
dc.contributor.googleauthor | Kwon, Oh-Kyong | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DEPARTMENT OF ELECTRONIC ENGINEERING | - |
dc.identifier.pid | okwon | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.