243 0

조립형 건식벽체의 차음성능 개선 공법에 관한 연구

Title
조립형 건식벽체의 차음성능 개선 공법에 관한 연구
Other Titles
Method of how to improve transmission loss of dry walls
Author
전진용
Keywords
Transmission loss(투과손실); M-bar Stud Acoustic(MSA구조); Runner(런너); Sound leak(음누설)
Issue Date
2013-04
Publisher
한국소음진동공학회
Citation
한국소음진동공학회 논문집, Apr 2013, P.719-724
Abstract
In the case of newly developed stud which has more performance of sound transmission loss, it is expected that sound would transmit through runner than stud. so we developed construction method of runner and stud. As a result, sound transmission loss is improved about 2 dB by using this method. But this construction method could be applied to only newly developed stud. In addition, sound leak of wall joint is about 2 dB, and it could be improved by using rubber gasket at joint.