352 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2018-03-23T06:47:54Z-
dc.date.available2018-03-23T06:47:54Z-
dc.date.issued2011-01-
dc.identifier.citationJournal of Instrumentation, 2011, 6(1), P.C01024-C01024en_US
dc.identifier.issn1748-0221-
dc.identifier.urihttp://iopscience.iop.org/article/10.1088/1748-0221/6/01/C01024/meta-
dc.description.abstractIn proton therapy, it is important to very accurately determine the range of the proton beam. Recently it was found that this range can be determined from the distribution of the prompt gammas generated along the beam's passage. The Compton imaging technique can be considered to be a promising candidate for accurate determination of prompt gamma distributions, in that it produces a better image for higher-energy gammas when compared with conventional mechanical-collimation- type imagers. In the present study, the Compton imaging technique was evaluated by experimentally obtaining Compton images of relatively high-energy gamma sources positioned in an anthropomorphic phantom. Preparatory to that, two point-like gamma sources, Cs-137 (662 keV) and Na-22 (1275 keV), were placed in the brain region of the phantom at different depths and imaged using a double-scattering Compton camera. The Compton camera, recently developed as a prototype system, consists of two position-sensitive semiconductor detectors as scatterer detectors and a scintillation detector as an absorber detector. The evaluated imaging and angular resolutions for the source energies of 662 and 1275 keV were 13.7 mm and 5.9 degrees FWHM and 11.4 mm and 3.8 degrees FWHM, respectively.en_US
dc.description.sponsorshipThis work was supported by the Nuclear Research and Development Program in Korea through the Radiation Technology Development Program and the Basic Research Program. Support was received also from the Korean Ministry of Knowledge Economy (2008-P-EP-HM-E-06-0000) / the Sunkwang Atomic Energy Safety Co., Ltd.en_US
dc.language.isoenen_US
dc.publisherIOP Publishing LTDen_US
dc.subjectCompton imagingen_US
dc.subjectInstrumentation for hadron therapyen_US
dc.subjectInstrumentation for heavyion therapyen_US
dc.titleExperimental performance of double-scattering Compton camera with anthropomorphic phantomen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume6-
dc.identifier.doi10.1088/1748-0221/6/01/C01024-
dc.relation.page1-5-
dc.relation.journalJOURNAL OF INSTRUMENTATION-
dc.contributor.googleauthorSeo, H.-
dc.contributor.googleauthorPark, J. H.-
dc.contributor.googleauthorUshakov, A.-
dc.contributor.googleauthorKim, C. H.-
dc.contributor.googleauthorKim, J. K.-
dc.contributor.googleauthorLee, J. H.-
dc.contributor.googleauthorLee, C. S.-
dc.contributor.googleauthorLee, J. S.-
dc.relation.code2011216807-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE