368 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author태경-
dc.date.accessioned2018-03-16T07:01:15Z-
dc.date.available2018-03-16T07:01:15Z-
dc.date.issued2014-04-
dc.identifier.citationThe Laryngoscope, 2014, 124(4), P.1042-1047en_US
dc.identifier.issn0023-852X-
dc.identifier.issn1531-4995-
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/abs/10.1002/lary.24511-
dc.description.abstractObjectives/Hypothesis The aim of this study was to investigate the surgical completeness of robotic total thyroidectomy compared with conventional open thyroidectomy. Study Design Retrospective, case?control study. Methods We studied 245 patients with papillary thyroid carcinoma who underwent total thyroidectomy and postoperative radioactive iodine (RAI) ablation. Of these, 62 patients underwent robotic thyroidectomy by a gasless unilateral axillo?breast (GUAB) or axillary (GUA) approach, and 183 underwent conventional open thyroidectomy. We analyzed serum TSH?stimulated thyroglobulin (Tg) and RAI uptake at the time of RAI remnant ablation to compare surgical completeness in the two groups. Results Tumor characteristics and complications did not differ between the two groups except TNM stage. The mean TSH?stimulated Tg at the first RAI ablation was significantly higher in the robotic group (10.20?±?9.98 ng/ml) than in the open group (3.85?±?6.79 ng/ml) (P <0.001). In subgroup analysis of the robotic group by the period in which operations took place, TSH?stimulated Tg was significantly higher than in the open group in the first (13.28?±?11.91 ng/ml) and second (10.45?±?9.30 ng/ml) periods, but there was no significant difference in the third period (6.00?±?6.26 ng/ml, P?=?0.141). The RAI uptake rate at the first RAI ablation did not differ between the two groups, and TSH?stimulated Tg after RAI ablation was similar. Conclusion The surgical completeness of robotic total thyroidectomy by a GUAB/GUB approach is comparable to that of open thyroidectomy, if performed by experienced robotic thyroid surgeons in properly selected patients. Level of Evidence 3b. Laryngoscope, 124:1042?1047, 2014en_US
dc.language.isoenen_US
dc.publisherWiley-Blackwellen_US
dc.subjectRobotic thyroidectomyen_US
dc.subjectgasless unilateral axillo?breast approachen_US
dc.subjectgasless unilateral axillary approachen_US
dc.subjectpapillary thyroid carcinomaen_US
dc.subjectendoscopic thyroidectomyen_US
dc.titleComparison of surgical completeness between robotic total thyroidectomy versus open thyroidectomyen_US
dc.typeArticleen_US
dc.relation.volume124-
dc.identifier.doi10.1002/lary.24511-
dc.relation.page1042-1047-
dc.relation.journalLARYNGOSCOPE-
dc.contributor.googleauthorTae, K.-
dc.contributor.googleauthorSong, C. M.-
dc.contributor.googleauthorJi, Y. B.-
dc.contributor.googleauthorKim, K. R.-
dc.contributor.googleauthorKim, J. Y.-
dc.contributor.googleauthorChoi, Y. Y.-
dc.relation.code2014035332-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidkytae-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE