233 0

Parametric response mapping of dynamic CT as an imaging biomarker to distinguish viability of hepatocellular carcinoma treated with transcatheter arterial chemoembolization

Title
Parametric response mapping of dynamic CT as an imaging biomarker to distinguish viability of hepatocellular carcinoma treated with transcatheter arterial chemoembolization
Author
이종민
Keywords
Hepatocellular carcinoma; Parametric response mapping; Automatic classifier; Transcatheter arterial chemoembolization; Dynamic CT; Longitudinal exam
Issue Date
2014-06
Publisher
SPRINGER, 233 SPRING ST, NEW YORK, NY 10013 USA
Citation
ABDOMINAL IMAGING, 권: 39 호: 3, p 518-525
Abstract
Accurate assessment of viability of hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE) is important for therapy planning. The purpose of this study is to determine the diagnostic value of a novel image analysis method called parametric response mapping (PRM) in predicting viability of tumor in HCC treated with TACE for dynamic CT images. 35 patients who had 35 iodized-oil defect areas (IODAs) in HCCs treated with TACE were included in our study. These patients were divided into two groups, one group with viable tumors (n = 22) and the other group with non-viable tumors (n = 13) in the IODA. All patients were followed up using triple-phase dynamic CT after the treatment. We compared (a) manual analysis, (b) using PRM results, and (c) using PRM results with automatic classifier to distinguish between two tumor groups based on dynamic CT images from two longitudinal exams. Two radiologists performed the manual analysis. The PRM approach was implemented using prototype software. We adopted an off-the-shelf k nearest neighbor (kNN) classifier and leave-one-out cross-validation for the third approach. The area under the curve (AUC) values were compared for three approaches. Manual analysis yielded AUC of 0.74, using PRM results yielded AUC of 0.84, and using PRM results with an automatic classifier yielded AUC of 0.87. We improved upon the standard manual analysis approach by adopting a novel image analysis method of PRM combined with an automatic classifier.
URI
http://link.springer.com/article/10.1007/s00261-014-0087-zhttp://hdl.handle.net/20.500.11754/47460
ISSN
0942-8925; 1432-0509
DOI
10.1007/s00261-014-0087-z
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE