223 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author심재항-
dc.date.accessioned2018-03-11T01:38:37Z-
dc.date.available2018-03-11T01:38:37Z-
dc.date.issued2013-02-
dc.identifier.citationAnaesthesia , 68, 6, 585 - 590en_US
dc.identifier.issn0003-2409-
dc.identifier.urihttp://onlinelibrary.wiley.com/doi/10.1111/anae.12219/abstract;jsessionid=61AAB2972A4822B2C30050EF5DB5140E.f02t04-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/44845-
dc.description.abstractThe GlideScope® videolaryngoscope is widely used in the management of the difficult airway. However, passing the tracheal tube through the vocal cords can be awkward, and the use of a stylet to guide insertion is recommended. This randomised controlled trial evaluated a forceps-guided tube exchanger as an alternative to the stylet to aid intubation with the GlideScope in patients undergoing anaesthesia, with a simulated difficult airway created by the application of a semi-rigid cervical collar. Data were analysed from 178 patients randomly assigned to undergo intubation using either the stylet (n = 88) or a forceps-guided tube exchanger (n = 90). All intubations were completed successfully, with first attempt rates of 93.2% using the stylet and 94.4% using the exchanger (p = 0.597). The mean (SD) intubation time was 67.8 (28.7) s in the stylet group and 66.1 (15.5) s in the forceps-guided tube exchanger group (p = 0.11). The frequency of sore throat 1 h after extubation was 34.1% in the stylet group and 2.2% in the tube exchanger group (p < 0.001); 24 h after extubation the corresponding figures were 40.0% and 11.1% (p < 0.001). Using a forceps-guided tube exchanger may offer an advantage over a stylet in guiding tracheal intubation when the GlideScope is used.en_US
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.subjectAdolescenten_US
dc.subjectAdulten_US
dc.subjectAgeden_US
dc.subjectEquipment Designen_US
dc.subjectIntubationen_US
dc.subjectinstrumentationen_US
dc.subjectmethodsen_US
dc.subjectLaryngoscopesen_US
dc.subjectMiddle Ageden_US
dc.subjectSurgical Instrumentsen_US
dc.subjectVideo Recordingen_US
dc.subjectYoung Adulten_US
dc.titleStylet- or forceps-guided tube exchanger to facilitate GlideScope (R) intubation in simulated difficult intubations - a randomised controlled trialen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume68-
dc.identifier.doi10.1111/anae.12219-
dc.relation.page585-590-
dc.relation.journalANAESTHESIA-
dc.contributor.googleauthorJeon, W. J.-
dc.contributor.googleauthorShim, J. H.-
dc.contributor.googleauthorCho, S. Y.-
dc.contributor.googleauthorBaek, S. J.-
dc.relation.code2013008826-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidjhshim-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE