295 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author유은종-
dc.date.accessioned2018-02-26T07:01:07Z-
dc.date.available2018-02-26T07:01:07Z-
dc.date.issued2016-03-
dc.identifier.citationJOURNAL OF VIBROENGINEERING, v. 18, NO 2, Page. 1031-1040en_US
dc.identifier.issn1392-8716-
dc.identifier.urihttp://www.jve.lt/Vibro/JVE-2016-18-2/JVE01816031949.html-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/40632-
dc.description.abstractThe most important thing in applying mass type dampers including Liquid Column Vibration Absorber (LCVA) is tuning its natural frequency to an optimum value which is a function of the natural frequency of the building and the mass ratio of damper to the building. However, exact prediction of the natural frequency of the building at design stage is very difficult especially for concrete buildings. Thus, continuous updating of the target frequency and correction of the design of the damper based on field measurement is necessary. In this paper, application of LCVAs to mitigate the wind-induced vibration of 64-story residential buildings is presented. The LCVA were designed to have adjustable dimension for vertical column to take the advantage of ease tuning and wide frequency range. For updating of initial design, the tuning and performance assessment of LCVA several tests and measurement were carried out. The ambient vibration measurement of a partially completed building and a completed building without water in LCVA was performed and final values of the width of vertical column and the height of water were determined from the system identification results based on the collected acceleration data. In addition, ambient vibration measurement of buildings with LCVA water was performed and the system identification results indicated that the apparent damping ratio due to LCVA was increased about 3.13 to 3.89 times.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korean Government (MSIP) (NRF-2010-0023976).en_US
dc.language.isoenen_US
dc.publisherJOURNAL VIBROENGINEERINGen_US
dc.subjectLCVAen_US
dc.subjectTLCDen_US
dc.subjectwind-induced vibrationen_US
dc.subjecttall buildingen_US
dc.subjectvibration controlen_US
dc.titleMitigation of wind-induced vibration of a tall residential building using liquid column vibration absorberen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume18-
dc.relation.page1031-1040-
dc.relation.journalJOURNAL OF VIBROENGINEERING-
dc.contributor.googleauthorCho, Bong-Ho-
dc.contributor.googleauthorYu, Eunjong-
dc.contributor.googleauthorKim, Hongjin-
dc.relation.code2016003847-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pideunjongyu-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE