Reclosing operation characteristics of the flux-coupling type SFCL in a single-line-to ground fault

Title
Reclosing operation characteristics of the flux-coupling type SFCL in a single-line-to ground fault
Author
성태현
Keywords
Superconducting fault current limiter; Recloser; Quench; Reclosing time; Recovery time of the superconducting elements
Issue Date
2011-10
Publisher
ELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS
Citation
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 권: 471, 호: 21-22, 페이지: 1327-1331
Abstract
The recloser that is used in distribution systems is a relay system that behaves sequentially to protect power systems from transient and continuous faults. This reclosing operation of the recloser can improve the reliability and stability of the power supply. For cooperation with this recloser, the superconducting fault current limiter (SFCL) must properly perform the reclosing operation. This paper analyzed the reclosing operation characteristics of the three-phase flux-coupling type SFCL in the event of a ground fault. The fault current limiting characteristics according to the changing number of turns of the primary and secondary coils were examined. As the number of turns of the first coil increased, the first maximum fault current decreased. Furthermore, the voltage of the quenched superconducting element also decreased. This means that the power burden of the superconducting element decreases based on the increasing number of turns of the primary coil. The fault current limiting characteristic of the SFCL according to the reclosing time limited the fault current within a 0.5 cycles (8 ms), which is shorter than the closing time of the recloser. In other words, the superconducting element returned to the superconducting state before the second fault and normally performed the fault current limiting operation. If the SFCL did not recover before the recloser reclosing time, the normal current that was flowing in the transmission line after the recovery of the SFCL from the fault would have been limited and would have caused losses. Therefore, the fast recovery time of a SFCL is critical to its cooperation with the protection system. (C) 2011 Elsevier B.V. All rights reserved.
URI
http://www.sciencedirect.com/science/article/pii/S0921453411002759?via%3Dihubhttp://hdl.handle.net/20.500.11754/40140
ISSN
0921-4534
DOI
10.1016/j.physc.2011.05.188
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE