Performance Evaluation of TMD under Typhoon Using System Identification and Inverse Wind Load Estimation
- Title
- Performance Evaluation of TMD under Typhoon Using System Identification and Inverse Wind Load Estimation
- Author
- 유은종
- Keywords
- PERFORMANCE evaluation; SYSTEM identification; TUNED mass dampers; WIND pressure; STEEL buildings; KALMAN filtering
- Issue Date
- 2012-02
- Publisher
- WILEY-BLACKWELL, 111 RIVER ST, HOBOKEN 07030-5774, NJ USA
- Citation
- Computer-Aided Civil & Infrastructure Engineering. Jul2012, Vol. 27 Issue 6, p455-473. 19p. 3 Black and White Photographs, 1 Diagram, 2 Charts, 14 Graphs.
- Abstract
- The typhoon behavior and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse modal wind load estimation. The TMD was installed on a 39-story, 184.6-m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet-based data logging system. On September 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. To analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. The analysis results show that the typhoon-induced vibration was reduced significantly due to the installation of TMD.
- URI
- http://onlinelibrary.wiley.com/doi/10.1111/j.1467-8667.2011.00755.x/abstract
- ISSN
- 1093-9687
- DOI
- 10.1111/j.1467-8667.2011.00755.x
- Appears in Collections:
- COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML