1024 79

Full metadata record

DC FieldValueLanguage
dc.contributor.author전래희-
dc.date.accessioned2018-01-30T05:52:38Z-
dc.date.available2018-01-30T05:52:38Z-
dc.date.issued2011-01-
dc.identifier.citationLaboratory Medicine Online, 2011, 1(1), P.35-42(8)en_US
dc.identifier.issn2093-6338-
dc.identifier.urihttps://synapse.koreamed.org/DOIx.php?id=10.3343/lmo.2011.1.1.6-
dc.description.abstractBackground: Measurements of serum anti-thyroglobulin antibody (anti-Tg) and anti-thyroid peroxidase antibody (anti-TPO) are important for the diagnosis of autoimmune thyroid diseases. Although ELISA is most commonly used for the detection of anti-thyroid autoantibodies, other methods like particle agglutination assay (PA) or radioimmunoassay (RIA) are still being used in clinical laboratories. There are few studies about the comparison between PA and ELISA, and we evaluated the validity of these assays in this study. Methods: We have used three methods, PA (Fujirebio Inc.), ELISA-1 (Zeus Scientific Inc.), and ELISA-2 (Orgentec Diagnostika) for the measurements of titers or concentrations of anti-thyroid autoantibodies. A total of 212 patients belonging to six different disease groups were tested: 40 patients for anti-Tg only, 64 for anti-TPO (or anti-microsome) only, and 108 for both antibodies. All test results were compared with each other in six disease groups. Results: Concordance of positive or negative results was obtained in 78.5-97.3% of the samples tested, and positive rates of three methods were similar in autoimmume thyroid disease group. In the comparable concentration range, the correlation coefficients were 0.328-0.820 between the two ELISAs or between ELISA and PA. Conclusions: Positive or negative decisions by three assay systems have high concordance rates, and antibody levels measured by three methods correlate well in the comparable concentration range. The ELISA-1 shows less non-specific reactions, better discrimination in low level of autoantibodies, and the highest positive rate in autoimmume thyroid disease group.en_US
dc.language.isoko_KRen_US
dc.publisher대한진단검사의학회en_US
dc.subjectAnti-thyroglobulin antibodyen_US
dc.subjectELISAen_US
dc.subjectParticle agglutination assayen_US
dc.subjectAnti-thyroid peroxidase antibodyen_US
dc.title갑상선 자가항체 검사를 위한 입자 응집법과 ELISA법의 비교en_US
dc.title.alternativeComparison of Particle Agglutination Assay and ELISA for Anti-thyroid Autoantibodiesen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume1-
dc.identifier.doi10.3343/lmo.2011.1.1.6-
dc.relation.page35-42-
dc.relation.journalLaboratory Medicine Online-
dc.contributor.googleauthor신경수-
dc.contributor.googleauthor전래희-
dc.contributor.googleauthor김신규-
dc.contributor.googleauthorShin, Kyoung-Soo-
dc.contributor.googleauthorJearn, La-He-
dc.contributor.googleauthorKim, Think-You-
dc.relation.code2012233347-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidlhchun-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE