dc.contributor.author정진욱-
dc.date.accessioned2017-10-16T02:18:07Z-
dc.date.available2017-10-16T02:18:07Z-
dc.date.issued2015-12-
dc.identifier.citationREVIEW OF SCIENTIFIC INSTRUMENTS, v. 86, NO 12, Article number 123502, Page. 1-5en_US
dc.identifier.issn0034-6748-
dc.identifier.issn1089-7623-
dc.identifier.urihttp://aip.scitation.org/doi/10.1063/1.4936770-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/30031-
dc.description.abstractAn in-situ real-time processing chamber wall monitoring system was developed. In order to measure the thickness of the dielectric film, two frequencies of small sinusoidal voltage (similar to 1 V) signals were applied to an electrically floated planar type probe, which is positioned at chamber wall surface, and the amplitudes of the currents and the phase differences between the voltage and current were measured. By using an equivalent sheath circuit model including a sheath capacitance, the dielectric thickness can be obtained. Experiments were performed in various plasma condition, and reliable dielectric film thickness was obtained regardless of the plasma properties. In addition, availability in commercial chamber for plasma enhanced chemical vapor deposition was verified. This study is expected to contribute to the control of etching and deposition processes and optimization of periodic maintenance in semiconductor manufacturing process. (C) 2015 AIP Publishing LLC.en_US
dc.description.sponsorshipThis research was supported by the Converging Research Center Program (No. NRF-2014M3C1A8053701), the National R&D Program (No. NRF-2014M1A7A1A03045185), the Technology Innovation Program (No. 10050500), and a Semiconductor Industry Collaborative Project between Hanyang University and Samsung Electronics Co. Ltd.en_US
dc.language.isoenen_US
dc.publisherAMER INST PHYSICSen_US
dc.subjectREACTORen_US
dc.titleReal-time dielectric-film thickness measurement system for plasma processing chamber wall monitoringen_US
dc.typeArticleen_US
dc.relation.no12-
dc.relation.volume86-
dc.identifier.doi10.1063/1.4936770-
dc.relation.page1-5-
dc.relation.journalREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.contributor.googleauthorKim, Jin-Yong-
dc.contributor.googleauthorChung, Chin-Wook-
dc.relation.code2015002893-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING-
dc.identifier.pidjoykang-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE