346 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2017-07-26T06:16:17Z-
dc.date.available2017-07-26T06:16:17Z-
dc.date.issued2015-10-
dc.identifier.citation대한건축학회 창립70주년기념대회 및 추계학술발표대회논문집 제35권 제2호(통권 제64집), 2015.10, 371-372en_US
dc.identifier.issn2287-5786-
dc.identifier.urihttp://www.dbpia.co.kr/Article/NODE06524778-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/28033-
dc.description.abstractThe main purpose of this paper is to analyze the characteristics and the performances of dedicated outdoor air system (DOAS) and desiccant-enhanced evaporative air conditioner (DEVap). The systems take two different air handling strategies. DOAS, mainly used for enhancing indoor air quality and humidity rate, is compromised of constant flow air handling unit and additional parallel cooling system. On the other hand, DEVap takes advantages of liquid desiccant system and regenerative indirect evaporative cooler with variable air flow rate. Although DOAS and DEVap are different in terms of their system compositions and the mode of operations, performance comparison of the systems is necessary to investigate more effective and energy conservative system. The primary energy as well as cooling and dehumidification capacities of two systems during summer season are analyzed through computer simulation with a commercial equation solver and a TRNSYS 17 program. As a result, DOAS conserved up to 61% of the primary energy and showed better cooling and dehumidification performance than DEVap.en_US
dc.description.sponsorship이 연구는 2015년도 정부(미래창조과학부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임.(No. 2015R1A2A1A05001726)en_US
dc.language.isoko_KRen_US
dc.publisher대한건축학회en_US
dc.subject외기전담 시스템en_US
dc.subject병렬냉방시스템en_US
dc.subject고성능 제습-증발 냉각 공조 시스템en_US
dc.subject정풍량 공조시스템en_US
dc.subject변풍량 공조시스템en_US
dc.subjectDedicated outdoor air system (DOAS)en_US
dc.subjectParallel cooling systemen_US
dc.subjectDesiccant enhanced evaporative air conditioneren_US
dc.subjectconstant air volume systemen_US
dc.subjectvariable air volume systemen_US
dc.title외기전담 시스템과 고성능 제습-증발냉각 시스템의 성능 비교 연구en_US
dc.title.alternativePerformance Comparison of the Dedicated Outdoor Air System and Desiccant-enhanced Evaporative Cooling systemen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume35-
dc.relation.page279-280-
dc.contributor.googleauthor김희정-
dc.contributor.googleauthor윤동섭-
dc.contributor.googleauthor정재원-
dc.contributor.googleauthorKim, Hui-Jeong-
dc.contributor.googleauthorYoon, Dong-Seob-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.