416 189

Full metadata record

DC FieldValueLanguage
dc.contributor.author엄기방-
dc.date.accessioned2016-05-27T01:01:13Z-
dc.date.available2016-05-27T01:01:13Z-
dc.date.issued2015-01-
dc.identifier.citationINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, v. 56/1, NO 1, Page. 21-28en_US
dc.identifier.issn0146-0404-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/21383-
dc.identifier.urihttp://iovs.arvojournals.org/article.aspx?articleid=2212751-
dc.description.abstractPURPOSE. To report the retinal nerve fiber layer (RNFL) defect volume deviation according to structural RNFL loss in RNFL thickness maps. METHODS. Retinal nerve fiber layer defect is defined in RNFL thickness maps by the degree of RNFL loss. A 20% to 70% degree of RNFL loss was set with a 1% interval as the reference level for determining the boundary of RNFL defects. Each individual RNFL thickness map was compared with a normative database map and the region below the reference level was identified as an RNFL defect. The RNFL defect volume was calculated by summing the volumes of each pixel inside RNFL defect. The RNFL defect volume deviation was calculated by summing the differences between the normative database and the subject's RNFL measurements. To evaluate the glaucoma diagnostic ability, the areas under the receiver operating characteristics curves (AUCs) were calculated. RESULTS. Retinal nerve fiber layer defect volume and RNFL defect volume deviation (0.984 and 0.986, respectively) had significantly greater AUCs than all circumpapillary RNFL thickness parameters (all P < 0.001). In the early stage of RNFL loss (under 31% loss of RNFL), RNFL defect volume deviation showed better diagnostic performance than the RNFL defect volume. In multivariate analysis, RNFL defect volume and RNFL defect volume deviation were significantly associated with the mean deviation in visual field tests. CONCLUSIONS. Retinal nerve fiber layer defect volume deviation is a useful tool for diagnosing glaucoma and monitoring RNFL change. In early stage of RNFL loss, RNFL defect volume deviation is more sensitive for detecting glaucoma than the RNFL defect volume measurements.en_US
dc.description.sponsorshipDisclosure: J.W. Shin, None; K.B. Uhm, None; M. Seong, None-
dc.language.isoenen_US
dc.publisherASSOC RESEARCH VISION OPHTHALMOLOGY INCen_US
dc.subjectspectral-domain optical coherence tomographyen_US
dc.subjectlost and remaining volumeen_US
dc.subjectretinal nerve fiber defecten_US
dc.subjectglaucomaen_US
dc.titleretinal nerve fiber layer defect volume deviation analysis using spectral-domain optical coherence tomographyen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume56/1-
dc.identifier.doi10.1167/iovs.14-15558-
dc.relation.page21-28-
dc.relation.journalINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE-
dc.contributor.googleauthor(Shin, Joong Won-
dc.contributor.googleauthorUhm, Ki Bang-
dc.contributor.googleauthorSeong, Mincheol-
dc.relation.code2015000081-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidkbuhm-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE