123 0

Removal of backside particles by a single wafer megasonic system

Title
Removal of backside particles by a single wafer megasonic system
Author
박진구
Issue Date
2007-00
Publisher
Electrochemical Society, Inc.
Citation
ECS Transactions, v. 11, NO. 2, Page. 95-100
Abstract
Single wafer megasonics were used to remove backside particle contamination resulting from vacuum chucks and chambers. Process evaluation was done using blanket wafer experiments with Si3N4 particles. To increase the difficulty of the particle removal test vehicle, aged contaminated wafers were used. The impact of film type, megasonic power, process chemicals and etch amount were investigated. The impact of performing a backside megasonic clean prior to the lithography process was shown. © The Electrochemical Society.