119 0

Investigation of Arc Behavior in HVDC LC Resonance Circuit Breaker Using Flexible Pulsed DC-Source

Title
Investigation of Arc Behavior in HVDC LC Resonance Circuit Breaker Using Flexible Pulsed DC-Source
Author
이방욱
Keywords
Black-box Model; DC Arcing Chamber; Flexible Pulsed DC source; HVDC LC Resonant Circuit Breaker
Issue Date
2018-09
Publisher
Institute of Electrical and Electronics Engineers Inc.
Citation
2018 Condition Monitoring and Diagnosis, CMD 2018 - Proceedings, article no. 8535906,
Abstract
As the multi-terminal HVDC systems are expanding, the needs for a HVDC circuit breaker is being enhanced to eliminate the adverse effects of a single pole fault on the whole system. However, there are challenges of dc interrupting that is due to the absence of the natural current zero point and the large rate of fault current (di / dt), which results in enormous interrupting energy. Therefore, the suitable circuit breaker topology that satisfy dc interrupting requirements have been widely studied. The passive resonance circuit breaker (PRCB) is one of the circuit breaker topologies that have been considered for HVDC system, and it is necessary to investigate the arc characteristics occurring in the main circuit breaker during opening operation. In this paper, a dc current source that generates a current pulse using semiconductor device IGBT switch and pre-charged capacitor was modeled, and Mayr black box model was used for analysis of arc characteristics. Unlike the conventional current source that generates the dc arc current using the L and C, the new current source can be arbitrarily selected for the current shape and the current slope without hardware modification and was used for measuring the steady state and transient state voltage-current characteristics of the switching arc. The black box Mayr model parameter values were calculated elaborately through the enhanced current source and the Levenberg-Marquardt Algorithm (LMA) widely used in the optimization technique was applied to the Mayr model to optimize the parameter values. © 2018 IEEE.
URI
https://ieeexplore.ieee.org/document/8535906https://repository.hanyang.ac.kr/handle/20.500.11754/178965
DOI
10.1109/CMD.2018.8535906
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE