279 0

인지부하의 정도에 따른 뇌신경생리학적 변화

Title
인지부하의 정도에 따른 뇌신경생리학적 변화
Other Titles
Changes in Electrophysiological Activation Due to Different Levels of Cognitive Load
Author
임창환
Keywords
Cognitive workload; n-back task; Electroencephalogram; Event-related potential; Event-related spectral perturbation; Source activity
Issue Date
2022-02
Publisher
대한의용생체공학회
Citation
의공학회지, v. 43, NO. 1, Page. 52-60
Abstract
For now, cognitive load is assessed based on survey-based methods, which can be difficult to track the amount of cognitive load in real-time. In this study, we investigated the difference in electrophysiological activation due to different levels of cognitive load not only at sensor-level but also at source-level using electro- encephalogram that might be potentially used for quantitative cognitive load evaluation. Materials and Methods: In this study, ten healthy subjects (mean age 24.3 ± 2.1, three female) participated the experiment. All participants performed 4 sessions of n-back task in different difficulties: 0-, 1-, 2-, and 3-back during electroencephalogram record- ing. For sensor-level analysis, we calculated the event-related potential and event-related spectral perturbation while low resolution brain electromagnetic tomography (LORETA) to estimate the source activation. Each result was com- pared between different workload conditions using statistical analysis. Results: Statistical results revealed that the accuracy of the task performance was significantly different between different cognitive loads (p = 0.018). The post- hoc analysis confirmed that the accuracy of the 3-back task was significantly decreased compared to 1-back condition (p = 0.018), but not with 2-back condition (p = 0.180). ERP results showed that P300 target amplitude between 1- back and 3-back had a marginal difference in Cz (p = 0.059) and Pz(p = 0.093). A significant inhibition in Cz high-beta activation (p = 0.017) and decrease in source activation of right parahippocampal gyrus was found in 3-back condition compared to 1-back condition (p < 0.05). Conclusion: In this study, we compared the sensor- and source-level dif- ferences in electroencephalogram between different levels of cognitive load, that were found to be in line with the previous reports related to cognitive load evaluation. We expect that the outcome of the current study can be used as a feature to establish a quantitative cognitive load assessment system.
URI
http://koreascience.or.kr/article/JAKO202209748207284.pagehttps://repository.hanyang.ac.kr/handle/20.500.11754/178046
ISSN
1229-0807;2288-9396
DOI
10.9718/JBER.2022.43.1.52
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE