112 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author유형석-
dc.date.accessioned2022-12-06T04:39:46Z-
dc.date.available2022-12-06T04:39:46Z-
dc.date.issued2021-05-
dc.identifier.citationIEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, v. 69, NO. 5, article no. 9234060, Page. 2560-2570en_US
dc.identifier.issn0018-926X;1558-2221en_US
dc.identifier.urihttps://ieeexplore.ieee.org/document/9234060en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/178020-
dc.description.abstractThis article presents rectangular and circular intravascular receive-only (Rx) open interior microcoils (MCs) for blood-vessel and brain-aneurysm imaging with two different magnetic resonance imaging (MRI) frequencies (128 and 298 MHz for field strengths 3 and 7 T, respectively). The proposed Rx MCs have a miniature volume of 4.92 mm(3). They offer a wider bandwidth, homogenous radio frequency (RF) receptivity, a high signal-to-noise ratio, and better vessel imaging than that offered by state-of-the-art MCs. In addition, they have open interiors that enable uninterrupted blood flow during MRI scanning and reduce motion artifacts. The proposed MCs were used to mimic different blood vessels of the brain, heart, neck, and kidneys in a realistic human voxel-based Duke model. We compared the reception efficiency (R-x,R-eff) and the sum of B-1(-) strengths (i.e., Sigma B-1(-)) in the region of interest (ROI) for the combined approach involving the birdcage (BC)/surface coil and the MC for various coil arrangements. The proposed MCs were fabricated and integrated with the 3-D-printed blood-vessel model. The simulation results indicate that the proposed MCs achieved the improvements of 72% and 75% in Sigma B-1(-) and R-x,R-eff, respectively, in the selected ROI (the blood vessel). Moreover, the MR images obtained by the proposed MCs exhibited high sensitivity of the blood signal and offered selective imaging of the arterial walls. According to the results, the proposed Rx MCs can be applied to perform intravascular imaging of smaller blood vessels.en_US
dc.description.sponsorshipThis work was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology under Grant 2019R1A2C2004774.en_US
dc.languageenen_US
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INCen_US
dc.subject3 Ten_US
dc.subject7 Ten_US
dc.subjectblood vesselen_US
dc.subjectimplantableen_US
dc.subjectmagnetic resonance imaging (MRI)en_US
dc.subjectradio frequency microcoils (RF MCs)en_US
dc.titleHigh-Resolution Implantable Microcoil Antennas for Blood-Vessel Imaging in High-Field MRIsen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume69-
dc.identifier.doi10.1109/TAP.2020.3030989en_US
dc.relation.page2560-2570-
dc.relation.journalIEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION-
dc.contributor.googleauthorUllah, Sana-
dc.contributor.googleauthorYoo, Hyoungsuk-
dc.sector.campusS-
dc.sector.daehak공과대학-
dc.sector.department바이오메디컬공학전공-
dc.identifier.pidhsyoo-
dc.identifier.orcidhttps://orcid.org/0000-0001-5567-2566-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles