106 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2022-11-21T01:23:23Z-
dc.date.available2022-11-21T01:23:23Z-
dc.date.issued2021-11-
dc.identifier.citationJOURNAL OF BUILDING ENGINEERING, v. 43, article no. 103213, Page. 1-12en_US
dc.identifier.issn2352-7102;2352-7102en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S2352710221010718?via%3Dihuben_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/177051-
dc.description.abstractMost hospitals use variable air volume systems to reduce their energy consumption while effectively responding to the frequently varying demands of cooling and heating. In this study, we applied the variable frequency drive (VFD) and variable pitch (VP) fan control methods to air handling units with axial fans in a tertiary hospital in Seoul, South Korea, and compared their power consumption and operating efficiencies according to the annual outdoor air intake rate schedule. The results of the comparison indicated that the VFD in the low-fan-output section and the VP method in the high-fan-output section consumed relatively less power. Concerning the economic feasibility analysis, we compared the annual operation and maintenance costs of the VFD and VP systems applied to the Air Handling Units (AHUs) in the hospital. In all cases, the annual energy consumption was lower in the VP than in the VFD; however, the VP was relatively high in maintenance and overhaul. It was shown that the VP is a more efficient control method due to the high-output operation of the AHUs for patient rooms. For other AHUs, the payback period was between 9 and 16 years when changing from VP to VFD.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea grant (No. 2019R1A2C2002514).en_US
dc.languageenen_US
dc.publisherELSEVIERen_US
dc.subjectAxial fanen_US
dc.subjectVariable air volumeen_US
dc.subjectHospitalen_US
dc.subjectAir handling uniten_US
dc.subjectVariable pitchen_US
dc.subjectVariable frequency driveen_US
dc.titleEnergy efficiency and economic analysis of variable frequency drive and variable pitch system: A case study of axial fan in hospitalen_US
dc.typeArticleen_US
dc.relation.volume43-
dc.identifier.doi10.1016/j.jobe.2021.103213en_US
dc.relation.page1-12-
dc.relation.journalJOURNAL OF BUILDING ENGINEERING-
dc.contributor.googleauthorSong, Il-Hak-
dc.contributor.googleauthorLhee, Jong-Ho-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.sector.campusS-
dc.sector.daehak공과대학-
dc.sector.department건축공학부-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE