Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-11-21T01:20:06Z | - |
dc.date.available | 2022-11-21T01:20:06Z | - |
dc.date.issued | 2021-12 | - |
dc.identifier.citation | SUSTAINABILITY, v. 13, NO. 24, article no. 14067, Page. 1-17 | en_US |
dc.identifier.issn | 2071-1050 | en_US |
dc.identifier.uri | https://www.mdpi.com/2071-1050/13/24/14067 | en_US |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/177049 | - |
dc.description.abstract | Comprehensively monitoring indoor environmental quality (IEQ) parameters and their dynamic relations is essential to ensure improved productivity and a healthy environment for building occupants. Although IEQ significantly influences working efficiency, studies addressing this aspect with researchers in institutes as the focal point are limited. Thus, this study employed drill-down analyses, such as floor-by-floor and building-by-building examinations and used an occupant IEQ survey approach to evaluate working conditions in research buildings. This study systematically and objectively assessed IEQ using the Korea building occupant survey system. The results indicate that acoustic qualities affect the work productivity and satisfaction of the building occupants. The floor-by-floor analysis is necessary to identify IEQ factors and the reasons for the satisfaction of occupants. Additionally, it is important to improve the user-friendliness of the system, implement frequent survey distribution systems, and empirically analyze data associations among building, spatial, and demographical characteristics. | en_US |
dc.description.sponsorship | This research was funded by the Major Project of the Korea Institute of Civil Engineering and Building Technology (KICT) (grant number 20210204-001) and (grant number 20200287-001). | en_US |
dc.language | en | en_US |
dc.publisher | MDPI | en_US |
dc.subject | indoor environmental quality (IEQ) | en_US |
dc.subject | occupant satisfaction | en_US |
dc.subject | research institute | en_US |
dc.subject | floor-by-floor analysis | en_US |
dc.title | Indoor environmental quality survey in research institute: A floor-by-floor analysis | en_US |
dc.type | Article | en_US |
dc.relation.no | 24 | - |
dc.relation.volume | 13 | - |
dc.identifier.doi | 10.3390/su132414067 | en_US |
dc.relation.page | 1-17 | - |
dc.relation.journal | SUSTAINABILITY | - |
dc.contributor.googleauthor | Lee, Jong-Won | - |
dc.contributor.googleauthor | Kim, Deuk-Woo | - |
dc.contributor.googleauthor | Lee, Seung-Eon | - |
dc.contributor.googleauthor | Jeong, Jae-Weon | - |
dc.sector.campus | S | - |
dc.sector.daehak | 공과대학 | - |
dc.sector.department | 건축공학부 | - |
dc.identifier.pid | jjwarc | - |
dc.identifier.orcid | https://orcid.org/0000-0002-5391-3298 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.