126 0

Corrosion of partially and fully debonded steel fibers from ultra-high-performance concrete and its influence on pullout resistance

Title
Corrosion of partially and fully debonded steel fibers from ultra-high-performance concrete and its influence on pullout resistance
Author
류두열
Keywords
Steel fiber corrosion; Pullout performance; Debonding state; Interfacial shear stress; Ultra-high-performance concrete
Issue Date
2021-11
Publisher
ELSEVIER SCI LTD
Citation
CEMENT & CONCRETE COMPOSITES, v. 124, article no. 104269, Page. 1-13
Abstract
The corrosion behaviors of partially and fully debonded steel fibers embedded in ultra-high-performance concrete (UHPC) and their impact on the pullout behavior were investigated. For this purpose, pre-loaded dog-bone samples were immersed in a 3.5% standard sodium chloride (NaCl) solution for 4, 10, and 20 weeks and then pull-out tested. The degree of corrosion on the fiber surface was determined by energy-dispersive X-ray spectroscopy. The test results indicated that the bond strength and pullout energy are improved by 54% and 90% maximally due to surface corrosion up to an immersion duration of 20 weeks. The effect of surface corrosion on the pullout properties was insignificantly influenced by the fiber pullout state (partially or fully debonded) up to 10 weeks, but the fully debonded fiber was prematurely ruptured at the longest duration of 20 weeks. The corrosion resistance of steel fiber in UHPC was earlier deteriorated, given the full debonding state (or the larger slip). The chemically debonded region was evidently corroded due to ferric oxide formation even after the shortest immersion duration of 4 weeks, whereas the bonded region with highly densified microstructures was insignificantly corroded. By surface corrosion, the pullout energy of the steel fiber in UHPC increased more significantly as compared with the average bond strength, owing to the twice or more frictional shear stress acting at the fiber-matrix interface.
URI
https://www.sciencedirect.com/science/article/pii/S0958946521003371?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/176927
ISSN
0958-9465;1873-393X
DOI
10.1016/j.cemconcomp.2021.104269
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE