138 0

Influence of horizontally variable soil properties on nonlinear seismic site response and ground motion coherency

Title
Influence of horizontally variable soil properties on nonlinear seismic site response and ground motion coherency
Author
박두희
Keywords
ground motion coherency; shear modulus reduction curve; shear wave velocity; site response; spatial variability
Issue Date
2022-03
Publisher
WILEY
Citation
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, v. 51, NO. 3, Page. 704-722
Abstract
The objective of this study is to quantify the effect of the spatial variability of soil properties on site response and ground motion coherency. A 2D random field theory is used to simulate soil parameters, including shear wave velocity (V-s) and nonlinear stress-strain curves. Different levels of spatial variability are controlled by coefficient of variation (COV) and correlation length (CL). The wave prorogation is simulated through the 2D finite difference software FLAC(2D). Different types of analysis conditions, such as 1D or 2D model, linear or nonlinear analysis, and input motion, are investigated. The increase of V-s variability leads to a decrease in the mean amplification ratio (surface response spectrum to bedrock response spectrum) but an increase in its variation. The effect of the variability of soil nonlinearity on the mean amplification ratio is marginal compared with that induced by V-s variability. However, as the ground motion intensities increase (or more nonlinearity induced), the standard deviation of the simulation normalized by the baseline response increases. Compared with the 2D result, the 1D site response analysis that is commonly used in practice may potentially underestimate the mean amplification ratio but overestimate its variability due to the ignorance of the horizontal soil property variability. In the evaluation of the spatially correlated site response, the ground motion coherency decays significantly, as the COV of V-s and the ground motion intensity increase. The effect of CL on ground motion coherency is minor and limited to a separation distance within two-times of CL. Therefore, a coherency model, which eliminates the CL term but includes the ground motion intensity (i.e., nonlinear effect) parameter, is proposed in this study. It is revealed to yield a better agreement with the simulation results than other coherency models.
URI
https://onlinelibrary.wiley.com/doi/10.1002/eqe.3587https://repository.hanyang.ac.kr/handle/20.500.11754/176785
ISSN
0098-8847;1096-9845
DOI
10.1002/eqe.3587
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE