222 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2022-10-14T04:03:48Z-
dc.date.available2022-10-14T04:03:48Z-
dc.date.issued2021-01-
dc.identifier.citationAPPLIED THERMAL ENGINEERING, v. 183, PART 2, article no. 116207, page. 1-15en_US
dc.identifier.issn1359-4311en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1359431120336863?via%3Dihuben_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/175396-
dc.description.abstractIn this study, two workable designs of a heat-pump-driven liquid desiccant (HPLD) air-conditioning system were proposed for residential buildings. The proposed HPLD systems were designed to work as a multi-functional air-conditioning system without additional equipment which would solve the low practicality due to the large scale and complexity of the conventional liquid-desiccant-assisted air-conditioning system. The critical difference between the two systems is the sump design for containing the desiccant solutions: Case A has a single sump instantly mixing weak and strong solutions, whereas Case B has dual sumps containing weak and strong solutions separately. The thermal load of target space was estimated using TRNSYS 18, and energy performances of both HPLD systems for summer and winter operation modes were analyzed using EES by integrating several established models and theoretical analyses. Owing to decrease in solution cooling and heating loads, the results show that Case B, compared with Case A, saved 28% of energy consumption and improved mean energy-efficiency by 37.5% for summer operation mode, and saved 12% of energy consumption and improved mean energy-efficiency by 4.95% for winter operation mode. In conclusion, Case B has a better application potential for residences in terms of energy performance.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) grant (No. 2019R1A2C2002514) and the Korean Institute of Energy Technology Evaluation and Planning (KETEP) (No. 20184010201710).en_US
dc.language.isoenen_US
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_US
dc.subjectLiquid desiccant; Heat pump; Energy performance; Residential buildingen_US
dc.titleDesign of heat pump-driven liquid desiccant air conditioning systems for residential buildingen_US
dc.typeArticleen_US
dc.relation.volume183-
dc.identifier.doi10.1016/j.applthermaleng.2020.116207en_US
dc.relation.page1-15-
dc.relation.journalAPPLIED THERMAL ENGINEERING-
dc.contributor.googleauthorLee, Jae-Hee-
dc.contributor.googleauthorKo, Jin-Young-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2021003275-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentSCHOOL OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE