180 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김현영-
dc.date.accessioned2022-05-17T00:27:37Z-
dc.date.available2022-05-17T00:27:37Z-
dc.date.issued2020-09-
dc.identifier.citationCLINICAL RADIOLOGY, v. 75, no. 9, article no. 714.e15en_US
dc.identifier.issn0009-9260-
dc.identifier.issn1365-229X-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0009926020302026?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/170894-
dc.description.abstractAIM: To differentiate dural arteriovenous fistula (DAVF) from reflux venous flow (RVF) by assessment of asymmetric enlargement of external carotid artery (ECA) branches on three-dimensional (3D) time-of-flight magnetic resonance angiography (TOF-MRA). MATERIALS AND METHODS: Nineteen patients with DAVF and 27 patients with RVF were included from September 2007 to April 2019. The locations of DAVF were the cavernous (n=9) and sigmoid-transverse (n=6) sinuses, and the jugular (n=3) and sphenoparietal (n=1) veins. Two radiologists visually assessed asymmetric enlargement of the ascending pharyngeal artery (ASP), middle meningeal artery (MMA), accessory meningeal artery (AMA), artery of the foramen rotundum, and occipital artery. MMA size was also measured quantitatively. RESULTS: More frequent asymmetric enlargement of the ASP and MMA were seen in DAVF than in RVF (17 of 19 versus 3 of 27 for ASP; 16 of 19 versus 1 of 27 for MMA, p<0.01). The AMA, artery of the foramen rotundum, and occipital arteries were not visualised in RVF patients. The ipsilateral MMA size was significantly larger in DAVF than in RVF (2.14 versus 0.64 mm(2), p<0.01). The diagnostic performance of ipsilateral MMA size for DAVF was good, with an area under the receiver operating characteristic curve of 0.89, with a sensitivity of 84.2% and a specificity of 81.5% at a cut-off of 1.08 mm(2). CONCLUSIONS: DAVF showed significantly larger ECA branches than RVF on 3D TOF-MRA. Therefore, thorough evaluation of ECA branches could help to differentiate DAVF from RVF.en_US
dc.description.sponsorshipThis work was supported by the research fund of Hanyang University (HY-2020).en_US
dc.language.isoenen_US
dc.publisherW B SAUNDERS CO LTDen_US
dc.subjectMIDDLE MENINGEAL ARTERYen_US
dc.subjectIMAGING FINDINGSen_US
dc.subjectRETROGRADE FLOWen_US
dc.subjectSINUSen_US
dc.subject3.0-Ten_US
dc.subjectVEINen_US
dc.titleDifferentiation of dural arteriovenous fistula from reflux venous flow on 3D TOF-MR angiography: identifying asymmetric enlargement of external carotid artery branchesen_US
dc.typeArticleen_US
dc.relation.no9-
dc.relation.volume75-
dc.identifier.doi10.1016/j.crad.2020.05.016-
dc.relation.page71415-71420-
dc.relation.journalCLINICAL RADIOLOGY-
dc.contributor.googleauthorLee, J.-
dc.contributor.googleauthorLee, J. Y.-
dc.contributor.googleauthorLee, Y-J-
dc.contributor.googleauthorPark, D. W.-
dc.contributor.googleauthorKim, T. Y.-
dc.contributor.googleauthorKim, Y. S.-
dc.contributor.googleauthorKim, H. Y.-
dc.relation.code2020054104-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidhyoungkim1-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE