204 0

산업용 송풍기의 진동저감에 관한 연구

Title
산업용 송풍기의 진동저감에 관한 연구
Other Titles
A Study on Vibration Reduction of an Industrial Fan
Author
정진태
Keywords
산업용 송풍기(Industrial Fan); 진동저감(Vibration Reduction); 모드해석(Modal analysis); 신호분석(Signal Analysis)
Issue Date
2000-06
Publisher
한국소음진동공학회
Citation
한국소음진동공학회지, v. 10, no. 3, page. 457-464
Abstract
Vibrations of a fan are often generated by mechanical unbalance, magnetic force and air flow. These vibrations depend on the design of a fan, the machining accuracy of each element and assembled conditions. An experimental study is carried out to reduce the vibration and noise of an industrial fan in this paper. In order to identify the vibration sources of a fan, the signal analysis and system analysis are performed. It is shown that the industrial fan studied in this paper has a natural frequency at 144 Hz and resonance occurs when the running speed of the fan is 1750 rpm. The results may be helpful to design a fan with low vibration and noise.
URI
https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02437774?https://repository.hanyang.ac.kr/handle/20.500.11754/161686