Performance evaluation of a tangential cyclone separator with additional inlets on the cone section

Title
Performance evaluation of a tangential cyclone separator with additional inlets on the cone section
Author
육세진
Keywords
Aerosol; Cyclone separator; Cut-off size; Collection efficiency; Pressure drop
Issue Date
2020-01
Publisher
ELSEVIER
Citation
POWDER TECHNOLOGY, v. 359, page. 118-125
Abstract
This study installed additional inlets on the cone section of a tangential cyclone separator and examined its effect on collection efficiency and pressure drop. When aerosol was injected through the additional inlets and clean air was injected into the original inlet, the cut-off size of particles decreased, compared to that when injecting aerosol through the original inlet. However, it was revealed that there was an optimal flowrate through the additional inlets to enhance the cyclone separator's performance. Meanwhile, injecting aerosol through not only the additional inlets but also the original inlet separated a higher flowrate of aerosol while demonstrating a similar level of collection efficiency and pressure drop compared to those of the reference cyclone separator. Therefore, installing additional inlets to the cone section of a conventional tangential cyclone separator is expected to process a higher flowrate of aerosol than the separator with similar performance, thereby increasing cost effectiveness. (C) 2019 Elsevier B.V. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S003259101930782X?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/160975
ISSN
0032-5910; 1873-328X
DOI
10.1016/j.powtec.2019.09.056
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE