283 0

Stretchable, patch-type calorie-expenditure measurement device based on pop-up shaped nanoscale-crack based sensor

Title
Stretchable, patch-type calorie-expenditure measurement device based on pop-up shaped nanoscale-crack based sensor
Author
정예환
Keywords
calories expenditure; nanoscale crack-based sensor (NCbS); pop-up shaped sensor; stretchable sensor
Issue Date
2019-10
Publisher
WILEY
Citation
ADVANCED HEALTHCARE MATERIALS, v. 8, no. 19, article no. 1801593
Abstract
Demands for precise health information tracking techniques are increasing, especially for daily dietry requirements to prevent obesity, diabetes, etc. Many commercially available sensors that detect dynamic motions of the body lack accuracy, while novel strain sensors at the research level mostly lack the capability to analyze measurements in real life conditions. Here, a stretchable, patch-type calorie expenditure measurement system is demonstrated that integrates an ultrasensitive crack-based strain sensor and Bluetooth-enabled wireless communication circuit to offer both accurate measurements and practical diagnosis of motion. The crack-based strain gauge transformed into a pop-up-shaped structure provides reliable measurements and broad range of strain (approximate to 100%). Combined with the stretchable analysis circuit, the skin attachable tool translates variation of the knee flexion angle into calorie expenditure amount, using relative resistance change (R/R-0) data from the flexible sensor. As signals from the knee joint angular movement translates velocity and walking/running behavior, the total amount of calorie expenditure is accurately analyzed. Finally, theoretical, experimental, and simulation analysis of signal stability, dynamic noises, and calorie expenditure calculation obtained from the device during exercise are demonstrated. For further applications, the devices are expected to be used in broader range of dynamic motion of the body for diagnosis of abnormalities and for rehabilitation.
URI
https://onlinelibrary.wiley.com/doi/full/10.1002/adhm.201801593https://repository.hanyang.ac.kr/handle/20.500.11754/160808
ISSN
2192-2640; 2192-2659
DOI
10.1002/adhm.201801593
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRONIC ENGINEERING(융합전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE