259 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2020-11-17T02:05:34Z-
dc.date.available2020-11-17T02:05:34Z-
dc.date.issued2019-11-
dc.identifier.citationENERGY AND BUILDINGS, v. 202, article no. UNSP 109387en_US
dc.identifier.issn0378-7788-
dc.identifier.issn1872-6178-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0378778819314185?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/155613-
dc.description.abstractPerformance simulations of thermoelectric radiant panels (TERPs) provide valuable information for the use of TERPs as alternatives to conventional hydraulic radiant panels, which require refrigerants based on the vapor compression cycle. Several existing models are appropriate for the design of the TERP; however, there are limitations to the building simulation with respect to the evaluation of the annual energy performance because existing models for TERP are based on the numerical method, therefore it is very complex to integrate with the building model. To overcome these limitations, simplified empirical models should be developed based on experimental data and then verified. This study aims to develop two simplified prediction models for the cooling capacity and energy consumption of TERPs. Using the 2(k) factorial experiment design method, a total of 16 experiment sets were designed according to the four main operation parameters: room temperature, outdoor air temperature, face velocity of air in duct, and combined heat transfer coefficient between room and panel surface. The developed models were designed in dimensionless forms to ensure broad applicability. The developed models yielded good R-2 values exceeding 0.99 and were validated under additional operation conditions. Finally, the guidance of using the developed models and the performance tables of the TERPs was confirmed with respect to the use of TERPs in the construction of heating, ventilation, and air conditioning (HVAC) systems. (c) 2019 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by the Korean Agency for Infrastructure Technology Advancement (KAIA) grants (19CTAP-C141826-02), by the Korean Institute of Energy Technology Evaluation and Planning (KETEP) (No. 20,184,010,201,710), and by the National Research Foundation of Korea (NRF) grant (No. 2019R1A2C2002514).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE SAen_US
dc.subjectThermoelectric refrigerationen_US
dc.subjectRadiant panel coolingen_US
dc.subjectNon-vapor compression systemen_US
dc.titleDevelopment of empirical models to predict cooling performance of a thermoelectric radiant panelen_US
dc.typeArticleen_US
dc.relation.volume202-
dc.identifier.doi10.1016/j.enbuild.2019.109387-
dc.relation.page1-13-
dc.relation.journalENERGY AND BUILDINGS-
dc.contributor.googleauthorLim, Hansol-
dc.contributor.googleauthorKang, Yong-Kwon-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2019039085-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
dc.identifier.researcherIDK-6463-2017-
dc.identifier.orcidhttps://orcid.org/0000-0002-5391-3298-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE